53
COMMISSIONING – Mountera® Box | REV. 1.0.1 | © 2020 Dallmeier
Position the insulated spade connector (fork ring crimp terminal)
of your earthing/grounding cable between the flat washer and the
external tooth lock washer as illustrated in Fig. 32.
External Earthing/Grounding Connections
The earthing/grounding cable coming from your main earthing terminal
can be connected either to the earthing/grounding connection point inside
the enclosure as illustrated in Fig. 16 on page 36 (recommended) or, if
required, to one of the two available external connection points (see below).
Fig. 32: M6 hexagon socket head cap screws (key size 5)
1. Housing
2. External tooth lock washer
3. Cable lug
4. Flat washer
5. Screw