DDZ40(10)(20)-YY/HS/HD
www.dallmeier.com
121
14.3.3
Scan
The scan function enables the PTZ dome camera to move automatically between two
user-defined positions at different speeds. This is very helpful if monitoring certain areas
frequently.
Scans can be called directly, assigned to actions or applied as “home” position.
SCAN SETUP
Number :01
Title :SCAN1
Mode :Normal
Speed :3 LEVEL
Start :None
End :None
Dir :CW
Swap :OFF
Dwell :03 Sec
Save and Exit
Number
01
–
16
Title
Up to 16 characters
Mode
Normal
:
Move from start point to end point in panning only
Diagonal
: Move from start point to end point including tilt and
zoom simultaneously and linearly
Speed
1
–
8 Level
(
1
: slower,
8
: faster)
Dir
Scan direction:
CCW
(Counter Clock Wise),
CW
(Clock Wise)
Swap
Swaps the start point for the end point if enabled (
ON
)
Dwell
Dwell time at the start and end point,
03
–
99
seconds
Select a number for the scan.
Edit the title of the scan (see section “
Select the scan mode.
Select the scan speed.
Edit the position of the start and end point (see section “
Set the scan direction.
Set the swap option.
Set the dwell time.
Execute
Save and Exit
.
To run a stored scan directly from the dome menu, go to
Run Function
in the main
DOME MENU
.