DMS 80 / DMS 160 / DMS 240 / DMS 240 HSR
www.dallmeier.com
48
Motion Estimate
This value specifies the estimated percentage of images with motion. It affects only the
estimated recording duration (
Estimate
) in the track.
6.4.1.3
Contact
In the Contact recording mode the recording is triggered by the recorder’s contact IN func-
tions. Contrary contact functions or completion of an
Option
will stop the recording.
Note that a contact input must be configured for the relevant camera (see section
Contact
IN
).
¾
Ensure that the
Expert Mode
option is activated.
¾
Set the
Contact
recording mode.
¾
Observe the explanations given below.
Fig. 6-22 :
Contact
recording mode
¾
Configure
Private Zones
if required (see section
Basic configuration
).
¾
Activate / configure the
Camera Timer
if required (see section
Basic configuration
).
¾
Activate the
Use Database
option if required.
¾
Set the
Pre-Event time
(see above).
¾
Set the
Contact Recording Duration
if required.
¾
Set the
Options
for contact recording.
¾
Confirm with
OK
.
Normal Single
A contact triggers the recording of an individual picture.
Normal sequencer
The recording is triggered by the contact switching. It continues until the contact is released
again.
Start
The recording is triggered by the contact switching. The recording is stopped by an op-
posite contact function (
Stop recording (Contact recording mode)
or
Stop recording
camera (Contact recording mode)
).