![dallmeier DMS 80 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dallmeier/dms-80/dms-80_configuration_3325139016.webp)
DMS 80 / DMS 160 / DMS 240 / DMS 240 HSR
www.dallmeier.com
16
¾
Set the
Datum format
.
¾
Set the
Time zone
.
¾
Configure the system time as described on the following pages.
5.2.1
Setting
The system time is provided by the internal RTC (Real Time Clock), if no external time
emitter is activated.
¾
Set the
Time
.
¾
Set the
Date
.
¾
Finally confirm with
OK
.
5.2.2
Time server
The recorder supports the
Network Time Protocol
(NTP). It can retrieve the system time
from an external time server via network.
Other NTP capable devices (e.g. IP cameras, recorders) always can use the recorder as a
time server in the network. This function is independent from the local settings.
¾
Activate the
Use external time server
check-box.
¾
Enter the
IP address
of the time server.
¾
Check the connection to the time server with
Ping
.
¾
Finally confirm with
OK
.
The time of the external time server is taken over as system time after the
restart of the
recorder.
5.2.3
Radio clock
The recorder can retrieve the system time from an external radio clock.
The USB radio clock
DFM-1-USB
is available for all Dallmeier recorders.
¾
Note the separate documentation for the radio clock.
¾
Ensure that the radio clock is connected.
¾
Activate the relevant interface in the
Radio Clock
section.
¾
Finally confirm with
OK.
The time of the external radio clock is taken over as system time after the
restart of the
recorder.
Status LED of the DFM-1-USB
Glowing red
no reception
Blinking red/green in a circle of one second
good reception
Blinking red/green in a unsteady circle
bad
reception