Only use the unit if it is technically in proper working condition and for the intended purpose while keeping safety and potential 
dangers in mind.

Qualified Personnel 
The installation, mounting, connection, commissioning and configuration of the unit may only be carried out by qualified 
personnel. This also applies to the maintenance, testing and repair, whereat the regulations of the DIN VDE 0701 series of 
standards (repair, modification and inspection of electrical appliances) must be followed.
Regulations
The use of video and audio surveillance systems is, in general, strictly regulated. Inform yourself about the currently valid 
laws and regulations regarding data, worker and environmental protection before using the unit and ensure compliance with 
them.
System Components
Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components can 
cause malfunctions, damages and data loss and can result in the loss of warranty.
RAID System
Devices that are configured with a RAID system for redundant recording always must be supplied with power via an uninter-
ruptable power supply (UPS). A sudden voltage drop can damage the RAID system.
Modifications
Do not make any modifications to the hardware or software that has not been tested and approved by Dallmeier. Inappropri-
ate modifications can cause malfunctions, damages and data loss and can result in the loss of warranty.
Documentation
Read the documents included in delivery carefully and thoroughly. Always observe the contained instructions, notes and 
warnings.
Condensation Water
If the unit is brought from a cold to a warm environment, resulting condensation water can cause malfunctions and damages. 
In this case, wait (up to 8 hours) until the unit has reached room temperature before commissioning.
Earthing & Equipotential Bonding
For the safety of persons (protection against dangerous contact voltages) and devices (protection against overvoltages) and 
the immunity of information and communication technology equipment to electromagnetic interferences (EMI), all protec-
tive measures, which are specified by the currently valid DIN, VDE and ISO standards and which provide for a standard-com-
pliant earthing and a correct equipotential bonding of electrical and electronic devices, are mandatory and must be fulfilled 
by all means.
Lightning Storms
To avoid damage to the unit by electrical surge during lightning storms, unplug the unit from the mains power supply (pull 
out the power plug). This is also recommended, when the unit has been unused for a long period of time.
Operating Conditions
Unfavourable operating conditions can shorten the life of the unit and can cause malfunctions, damages and data loss and 
can result in the loss of warranty. Observe the specifications given in the technical data, the operating condition requirements
and the maintenance instructions.
Shocks
Shocks can cause malfunctions and damages. The unit may not be moved while in operation.
Foreign Bodies
If objects or liquids get into the unit, immediately disconnect it from the power supply (pull out the power plug). Contact the 
sales partner responsible for your area.
Burnt Smell
If you notice burnt smell or a formation of smoke coming from the unit, immediately disconnect it from the power supply 
(pull out the power plug). Contact the sales partner responsible for your area.
Opening
The housing of the unit may only be opened by qualified personnel for commissioning, inspection, maintenance and repair.
Disposal
Do not dispose waste electrical and electronic equipment into the household trash. Disconnect the unit from the power sup-
ply. Remove all connected devices. Return the unit to your respective sales partner.

Safety Instructions

 

In

tr

oduc

tion

UT
P

NSU

Login

Multi-D H

D

Dimensions

Notes

 

Saf
ety
 

Instruc

tions

Installa

tion

 

Module

Содержание DIS-2/M Multi-D HD

Страница 1: ...Dallmeier DIS 2 M UTP DIS 2 M NSU DIS 2 M Multi D HD Commissioning 004076 1 0 0 2012 10 30 English...

Страница 2: ...faulty operations The following symbols and various character formats are used to increase the clearness of the document Instructions are indicated by arrows Expressions in bold italics generally indi...

Страница 3: ...thing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection against overvoltages and the immunity of information and communication techno...

Страница 4: ...ck The modules must later be installed in sequence from left to right WARNING Do not reach into the open housing of the module rack Do not insert any objects The module rack is already live This means...

Страница 5: ...ently lit Configure the IP address or DHCP as described in the Configuration documentation Then install the next module as described above The module and PC or laptop can also be connected direct usin...

Страница 6: ...DIN4 E UTP RS485 F Audio IN OUT 3 5mm phone jack 15 16 13 11 9 7 5 3 1 14 12 10 8 6 4 2 PIN Function 2 4 w o 6 Contact 1 8 Contact 2 10 Contact 3 12 Contact 4 14 16 GND PIN Function 1 3 Relay 1 5 7 R...

Страница 7: ...ntact OUT The output relays are floating and galvanically separated Value Condition Max Switch capacity max 12W Switch voltage DC or peak AC max 12V Switch current DC or peak AC max 1A Technical Data...

Страница 8: ...ined RS485 RS232 interface Technical Data Power supply 12V AC 5 Power consumption Max 25W Thermal output Max 85BTU h Temperature 5 C up to 40 C 41 F 104 F Humidity 5 70 RH non condensing Atmospheric l...

Страница 9: ...d as follows to sign up The default ip address is 10 2 6 98 the default password is 3 Start the browser Enter the required ip address The login dialogue is displayed Make the required settings see Con...

Страница 10: ...10 www dallmeier com Dimensions Variant 550 378mm 14 9 109mm 4 3 41mm 1 6 41mm 1 6 109mm 4 3 538mm 21 2 Variant 700...

Страница 11: ...11 Notes Safety Instructions Installation Module NSU UTP Dimensions Multi D HD Login Introduction Notes...

Страница 12: ...amages All rights reserved in the event of the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to proper...

Отзывы: