background image

Replacement Parts and Repair & Exchange Programs

15

parts that have been damaged due to acts of nature or causes other than normal 

wear and tear.

Repair & Return Program

For items not subject to exchange, Daktronics offers a Repair & Return Program. To send 

a part for repair, follow these steps:

1.  Call or fax Daktronics Customer Service:

  

Refer to the appropriate market number in the chart listed on the previous page. 

Fax: 605-692-0145

2.  Receive a case number before shipping

To receive a case number, contact a services coordinator via phone, email, or by 

creating a 

MySupport

 account on the Daktronics website. This expedites repair of the 

part.

3.  Package and pad the item carefully to prevent damage during shipment

Electronic components, such as printed circuit boards, should be placed in an 

antistatic bag before boxing. Daktronics does not recommend using packing 

peanuts when shipping. 

4. 

Enclose:
•  your name
•  address
•  phone number
•  the case number
•  a clear description of symptoms

To participate in the Exchange Program, follow these steps.

1.  Call Daktronics Customer Service:

 

2.  When the new exchange part is received, mail the old part to Daktronics.

 

If the replacement part fixes the problem, send in the problem part which is being 

replaced.

a. 

Package the old part in the same shipping materials in which the replacement 

part arrived.

b. 

Fill out and attach the enclosed UPS shipping document.

c. 

Ship the part to Daktronics.

3.  A charge will be made for the replacement part immediately, unless a qualifying 

service agreement is in place

. In most circumstances, the replacement part will be 

invoiced at the time it is shipped.

4.  If the replacement part does not solve the problem, return the part within 30 working 

days or the full purchase price will be charged

.  

If, after the exchange is made the equipment is still defective, please contact 

Customer Service immediately. Daktronics expects immediate return of an exchange 

part if it does not solve the problem. The company also reserves the right to refuse 

Market Description

Customer Service Number

Department of Transportation, mass transits, 

airports, parking facilities

800-833-3157

Содержание VS-5000 Series

Страница 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 GENERIC SERVICE VARIABLE SPEED LIMIT SIGNS VS 5000 SERIES DISPLAY MANUAL 30 May 2018 DD3907919 Rev 0...

Страница 2: ...art of this book covered by the copyrights hereon may be reproduced or copied in any form or by any means graphic electronic or mechanical including photocopying taping or information storage and retr...

Страница 3: ...8 Service and Diagnostics 8 Sign Controller Replacement 8 Accessing the Internal Components 9 Replacing a Module 9 Replacing a Power Supply 9 Ventilation Systems With Fans and Filters 10 Replacing a V...

Страница 4: ...ii This page intentionally left blank...

Страница 5: ...trical installation information for the sign Maintenance and Troubleshooting provides maintenance and troubleshooting information for Daktronics variable speed limit signs and the sign controller Repa...

Страница 6: ...e status of the signs and to control all messages A module is the building block of the Daktronics sign By placing modules side by side and on top of one another a sign of any size can be designed and...

Страница 7: ...controller The following table details some essential LEDs to monitor and the information each LED provides The LED name and number are noted in Figure 5 DS3 DS2 Figure 5 Controller Component Layout F...

Страница 8: ...performs the check and monitors the results Refer to Vanguard Software Help File F1 Power Supplies The power supply mounts to the cabinet truss behind module A102 The power supply provides the necessa...

Страница 9: ...d Do not attempt to permanently support the sign by the eyebolts Mounting Methods Securely mount each sign to a suitable mounting structure provided by others Have each mounting structure inspected by...

Страница 10: ...e 1 Remove the bottom three modules using a 1 8 hex head wrench Refer to Accessing the Internal Components p 9 for module removal steps 2 Clear the area for drilling Choose area free of wired componen...

Страница 11: ...ach controller in a network needs a unique address Refer to Figure 7 To set the rotary address switches rotate them counter clockwise until the arrow points to the desired number The display s power m...

Страница 12: ...r 9 V power supplies Ventilation fans and filters Beacons Thermostat Photo sensor The tools required to service the sign include Small Phillips screwdriver Small flat screwdriver 1 8 hex head wrench M...

Страница 13: ...move the module to service referring to Accessing the Internal Components p 9 3 Press the locking tabs of the white 4 pin power connector to release it Release the ribbon cable for signal 4 Remove the...

Страница 14: ...tion of dirt and debris change the filters more often Spin the fan blades with a pen or pencil to ensure the bearings are free and the fan is balanced Push the black button near GFCI outlet to check i...

Страница 15: ...of corrosion loose bolts and overall stability Check the connections of the earth ground wires if accessible Photo Sensor Assembly Inspection At least once every year Inspect the light sensor assembly...

Страница 16: ...e Solution No LEDs will light and the sign controller will not communicate with the central controller No power Check that the sign has power Sign controller or modem is bad Refer to Sign Controller R...

Страница 17: ...perature inside the sign exceeds the thermostat setting This is not a problem The thermostat is stuck on or the wiring is shorted Replace the thermostat or repair wiring LED brightness is wrong entire...

Страница 18: ...ingle enclosure Most circuit boards and components within this sign carry a label that lists the part number of the unit If a circuit board or assembly is not listed in the replacement parts list use...

Страница 19: ...of symptoms To participate in the Exchange Program follow these steps 1 Call Daktronics Customer Service 2 When the new exchange part is received mail the old part to Daktronics If the replacement pa...

Страница 20: ...Replacement Parts and Repair Exchange Programs 16 Shipping Address Daktronics Customer Service Case ____________ 331 32nd Ave Brookings SD 57006 E mail transportationhelp daktronics com...

Страница 21: ...le unit Multiple pixels are evenly spaced throughout the face of the sign and are turned on or off to form the characters and graphics that make up the content of the displayed message Power Supply A...

Отзывы: