Routine/Preventative Maintenance 

The service intervals listed in this section are recommendations. These service intervals 

can be adjusted if necessary due to special considerations. Contact Daktronics 

Customer Service for recommendations based upon specific conditions.

Sign Cabinet Inspection 

At least once every year:
•  Check for evidence of water intrusion in the sign, (i.e., water stain marks).
•  Check for any leaks that may have developed. Seal them with a silicone sealant or 

another suitable sealer.

•  Inspect all module gaskets for tears, missing pieces, etc. Replace as necessary.
•  Check the drain holes in the bottom of the cabinet to ensure they are unobstructed.

Sign Controller

At least once every year:
•  Ensure all connectors are secure and the cables are not damaged in any way.
•  Check the operation of the sign controller.

Structural Inspection 

At least once every year:
•  Inspect the mounting structure thoroughly for signs of corrosion, loose bolts, and 

overall stability.

•  Check the connections of the earth-ground wires, if accessible.

Photo Sensor Assembly Inspection 

At least once every year:
• 

Inspect the light sensor assembly for foreign material that could obstruct airflow 

around the photo sensors.

•  Clear away any foreign material.

LED Cleaning

If needed, clean the LEDs with a damp cloth or a soft brush. Do not spray cleaner directly 

onto the LEDs. The frequency the LEDs need cleaning depends on site conditions.

Ventilation System Inspection

At least once every year check that all the fans run. 
To do this, note the setting on the cooling thermostat and then turn it clockwise until the 

fans turn on. Make sure all fans are running. Press the black button to test the thermostat. 
After opening the intake fan assembly, check the fan blades for dirt and debris. If the fan 

blades have a large accumulation of dirt and debris, change the filters more often. Keep 

the fan blades clean to maintain fan efficiency and ensure proper cooling. Next, spin 

the fan blades with a pen or pencil to ensure the bearings are free and the fan is still in 

balance. 

Check and clean filter as necessary.

Содержание VS-5000 Series

Страница 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 GENERIC SERVICE VARIABLE SPEED LIMIT SIGNS VS 5000 SERIES DISPLAY MANUAL 30 May 2018 DD3907919 Rev 0...

Страница 2: ...art of this book covered by the copyrights hereon may be reproduced or copied in any form or by any means graphic electronic or mechanical including photocopying taping or information storage and retr...

Страница 3: ...8 Service and Diagnostics 8 Sign Controller Replacement 8 Accessing the Internal Components 9 Replacing a Module 9 Replacing a Power Supply 9 Ventilation Systems With Fans and Filters 10 Replacing a V...

Страница 4: ...ii This page intentionally left blank...

Страница 5: ...trical installation information for the sign Maintenance and Troubleshooting provides maintenance and troubleshooting information for Daktronics variable speed limit signs and the sign controller Repa...

Страница 6: ...e status of the signs and to control all messages A module is the building block of the Daktronics sign By placing modules side by side and on top of one another a sign of any size can be designed and...

Страница 7: ...controller The following table details some essential LEDs to monitor and the information each LED provides The LED name and number are noted in Figure 5 DS3 DS2 Figure 5 Controller Component Layout F...

Страница 8: ...performs the check and monitors the results Refer to Vanguard Software Help File F1 Power Supplies The power supply mounts to the cabinet truss behind module A102 The power supply provides the necessa...

Страница 9: ...d Do not attempt to permanently support the sign by the eyebolts Mounting Methods Securely mount each sign to a suitable mounting structure provided by others Have each mounting structure inspected by...

Страница 10: ...e 1 Remove the bottom three modules using a 1 8 hex head wrench Refer to Accessing the Internal Components p 9 for module removal steps 2 Clear the area for drilling Choose area free of wired componen...

Страница 11: ...ach controller in a network needs a unique address Refer to Figure 7 To set the rotary address switches rotate them counter clockwise until the arrow points to the desired number The display s power m...

Страница 12: ...r 9 V power supplies Ventilation fans and filters Beacons Thermostat Photo sensor The tools required to service the sign include Small Phillips screwdriver Small flat screwdriver 1 8 hex head wrench M...

Страница 13: ...move the module to service referring to Accessing the Internal Components p 9 3 Press the locking tabs of the white 4 pin power connector to release it Release the ribbon cable for signal 4 Remove the...

Страница 14: ...tion of dirt and debris change the filters more often Spin the fan blades with a pen or pencil to ensure the bearings are free and the fan is balanced Push the black button near GFCI outlet to check i...

Страница 15: ...of corrosion loose bolts and overall stability Check the connections of the earth ground wires if accessible Photo Sensor Assembly Inspection At least once every year Inspect the light sensor assembly...

Страница 16: ...e Solution No LEDs will light and the sign controller will not communicate with the central controller No power Check that the sign has power Sign controller or modem is bad Refer to Sign Controller R...

Страница 17: ...perature inside the sign exceeds the thermostat setting This is not a problem The thermostat is stuck on or the wiring is shorted Replace the thermostat or repair wiring LED brightness is wrong entire...

Страница 18: ...ingle enclosure Most circuit boards and components within this sign carry a label that lists the part number of the unit If a circuit board or assembly is not listed in the replacement parts list use...

Страница 19: ...of symptoms To participate in the Exchange Program follow these steps 1 Call Daktronics Customer Service 2 When the new exchange part is received mail the old part to Daktronics If the replacement pa...

Страница 20: ...Replacement Parts and Repair Exchange Programs 16 Shipping Address Daktronics Customer Service Case ____________ 331 32nd Ave Brookings SD 57006 E mail transportationhelp daktronics com...

Страница 21: ...le unit Multiple pixels are evenly spaced throughout the face of the sign and are turned on or off to form the characters and graphics that make up the content of the displayed message Power Supply A...

Отзывы: