16
Maintenance and Troubleshooting
5.3 7-Segment Error Codes
A 7-segment indicator appears on the following components; refer to
Figure 7
. The 7-segment indicator provides codes to indicate any present
errors and their cause. When an error occurs, the 7-segment will flash
the error code. If multiple errors are present, the 7-segment will flash the
errors individually in succession. If no errors are present, the 7-segment
will show a continuously looping figure-8.
Modules
7-Segment Error Code
Error
Cause
1
Communications Lost
No CAN packets received for
10 seconds
2
Failed Pixel
Refer to the troubleshooting
table in
Section
5.16.
3
Power Failure
Input Voltage has dropped
below 20 VDC
8
Lost Packet
Diagnostic packet, FIFO full
LVDB
7-Segment Error Code
Error
Cause
1
Communications Lost
No CAN packets for 10
seconds
2
Input voltage error
V-In < 22 VDC
3
Single fuse error
One fuse is blown
4
Multiple fuse error
Multiple fuses are blown
5.4 Internal Component Access
To access the internal components, open the face panel doors.
1.
Turn off display power.
2.
Use a hex wrench to unscrew the captive bolts at the top and bottom of the doors.
3.
Pull the door open; it hinges on the right side.
Figure 7: 7-Segment