background image

FLR3-100 Installation Quick Guide

13 June 2017
DD2291475
Rev 06

201 Daktronics Drive Brookings, SD 57006

www.daktronics.com/support

800.325.8766

Page 4 of 4

Option 1: Dedicated (Branch) Circuits

1.  Ensure a dedicated branch circuit is installed for each Fuelight system. This allows a power cycle for 

each Fuelight system so the keyfob can be synced only to that system.

2.  Shut off all power.
3. 

Power up the first Fuelight system and sync the keyfob per 

Section Mating the Key Fob With the 

Display (p. 2)

.

4. 

After the first Fuelight system and key fob are synced, shut off power to this circuit 

after 5 minutes

5.  Power up the second Fuelight system and sync that key fob. 
6. 

Shut down power after 5 minutes.

7.  Repeat this step for additional Fuelight systems. 
8. 

Once all key fobs are synced and marked to designate which Fuelight system they control, power 

up all branch circuits.

9.  Key fob synchronization is complete. 
10.  Map the lines of all of the displays in each of the Fuelight systems per 

Section Setting the Display Line 

Numbers (p. 2)

.

Option 2: Single Branch Circuit for All Fuelight Systems

Use this option when a single branch circuit is wired to all pylons and Fuelight systems.
All Fuelight systems turn off and on simultaneously requiring access to the inside of the host display of 

each Fuelight system to sync to its dedicated key fob.
1. 

In the host display of each Fuelight system, unplug the driver power supply.

2. 

Power up the first Fuelight system by reconnecting the power supply to the driver.

3.  Sync the keyfob per 

Section Mating the Key Fob With the Display (p. 2)

.

4. 

After the first Fuelight system and key fob are synced, disconnect the power supply from the driver 

after 5 minutes

5.  Power up the second Fuelight system by reconnecting the power supply to the driver and sync that 

key fob.

6. 

Unplug the power supply from the driver after 5 minutes. 

7.  Repeat this step for additional Fuelight systems. 
8. 

Once all key fobs are synced and marked to designate which Fuelight system they control, 

reconnect all power supplies to their drivers in all host displays.

9.  Key fob synchronization is complete. 
10.  Map the lines of all of the displays in each of the Fuelight systems per 

Section Setting the Display Line 

Numbers (p. 2)

.

Note: 

If there are multiple pylons, repeat the steps above for each pylon.

Note: 

Make sure only one pylon is powered on at a time.

Note: 

If there are multiple pylons, repeat the steps above for each pylon.

Note: 

Make sure only one pylon is powered on at a time.

Содержание FLR3-100

Страница 1: ...of the antenna cable and tighten using an 11 32 wrench 8 Thread the female end of the antenna on to the threaded end of the antenna cable and turn the antenna clockwise until snug Refer to Figure 2 9 Connect the receiver cable from receiver to the driver Refer to Figure 3 10 Neatly secure any excess cable with cable ties 11 Close and secure the digit face Setting the Security DIP Switches The FLR3...

Страница 2: ...he decimal begins to flash This takes about five seconds 3 While the display slowly flashes press the 2 button until the appropriate line number is shown on the display L01 L02 etc 4 Once the line number is set press and hold the 2 and 2 buttons until the next display face begins to slowly flash 5 Repeat these steps until all display faces have been correctly mapped 6 Exit configuration mode by pr...

Страница 3: ...nd holding the 4 and 4 buttons until the displays return to showing prices approximately five seconds Controlling Five or More Fuel Grades or Multiple Pylons Use the following steps when controlling more than four fuel grades in the same pylon or when more than one pylon exists on the same site Important Terms Host Display Display that has the receiver card connected to it Fuelight System Host dis...

Страница 4: ...ed to all pylons and Fuelight systems All Fuelight systems turn off and on simultaneously requiring access to the inside of the host display of each Fuelight system to sync to its dedicated key fob 1 In the host display of each Fuelight system unplug the driver power supply 2 Power up the first Fuelight system by reconnecting the power supply to the driver 3 Sync the keyfob per Section Mating the ...

Отзывы: