background image

FLR3-100 Installation Quick Guide

13 June 2017
DD2291475
Rev 06

201 Daktronics Drive Brookings, SD 57006

www.daktronics.com/support

800.325.8766

Page 3 of 4

Number Configuration

This section steps you through configuring the numbers six 

and nine and the fraction display preferences.
1.  Make sure display is turned on.
2.  Press and hold the -3 and +3 buttons on the key fob 

until all displays show the numbers 6 and 9. The number 

scheme will be either 3.69 9/10 or 4.69 9/10. Refer to 

Figure 5

.

3. 

Press the Plus (+) or Minus (-) keys to scroll through the 

different configuration options.

4. 

When the desired configuration is shown on the 

displays, press and hold the -3 and +3 buttons to exit 

configuration mode.

Entering Test Mode 

Entering test mode causes the displays to cycle through 

various pieces of information that can be useful when 

working with Daktronics Technical Support. 
1.  Press and hold the -4 and +4 buttons of the key fob until 

the displays begin cycling through test mode.

2.  Exit test mode by pressing and holding the -4 and +4 buttons until the displays return to showing 

prices; approximately five seconds.

Controlling Five or More Fuel Grades or Multiple Pylons

Use the following steps when controlling more than four fuel grades in the same pylon or when more 

than one pylon exists on the same site.

Important Terms

•  Host Display - Display that has the receiver card connected to it.
•  Fuelight System - Host display and all other displays that are connected to the host with a line to line 

cable.

No Tails and 9

No Tails and 9/10

Tails and 9

Tails and 9/10

Figure 5: 

Digit Configurations

No Tails and 9

Tails and 9

Figure 6: 

International Digit Configuration

Note: 

For Domestic displays with a 9/10s digit, the 

number 3 needs to show in the first column for 

the desired format. For International displays, 

make sure the number 4 shows in the first 

column for the desired format. 

Note: 

International displays offer two configuration 

options - tails and 9 and no tails and 9, as 

shown in 

Figure 6

.

Note: 

The same instructions apply to installation in a sign shop or on site.

Note: 

Two or more FLR3-100 key fobs are required.

Note: 

Each keyfob is limited to controlling a maximum of four grades and only displays a single pylon. 

Содержание FLR3-100

Страница 1: ...of the antenna cable and tighten using an 11 32 wrench 8 Thread the female end of the antenna on to the threaded end of the antenna cable and turn the antenna clockwise until snug Refer to Figure 2 9 Connect the receiver cable from receiver to the driver Refer to Figure 3 10 Neatly secure any excess cable with cable ties 11 Close and secure the digit face Setting the Security DIP Switches The FLR3...

Страница 2: ...he decimal begins to flash This takes about five seconds 3 While the display slowly flashes press the 2 button until the appropriate line number is shown on the display L01 L02 etc 4 Once the line number is set press and hold the 2 and 2 buttons until the next display face begins to slowly flash 5 Repeat these steps until all display faces have been correctly mapped 6 Exit configuration mode by pr...

Страница 3: ...nd holding the 4 and 4 buttons until the displays return to showing prices approximately five seconds Controlling Five or More Fuel Grades or Multiple Pylons Use the following steps when controlling more than four fuel grades in the same pylon or when more than one pylon exists on the same site Important Terms Host Display Display that has the receiver card connected to it Fuelight System Host dis...

Страница 4: ...ed to all pylons and Fuelight systems All Fuelight systems turn off and on simultaneously requiring access to the inside of the host display of each Fuelight system to sync to its dedicated key fob 1 In the host display of each Fuelight system unplug the driver power supply 2 Power up the first Fuelight system by reconnecting the power supply to the driver 3 Sync the keyfob per Section Mating the ...

Отзывы: