Config
22
Temperature
If the display is equipped with a temperature sensor, it may be necessary to enter an
offset. An offset compensates for environmental conditions such as a sensor mounted
too close to a heat source or in the shade. Such conditions will affect the accuracy of
the temperature reading by a specified amount (-9 °C to +9 °C). Enter an offset by typing
in a value in the
Offset
field or by moving the slider bar. The default offset is
0
.
Test Patterns
The
Test Patterns
drop-down list includes all test
patterns that are available on the VIP. Select one
of these test patterns to trigger the VIP to play it.
4000 Series
Choose the VIP
4000 Series
from the drop-down
list to open the configuration fields for the
Host
,
Config Port
,
Status Port
, and
Control Port
as well as
Brightness
,
Temperature
, and
Test Patterns
. Refer to
.
• Host
: default value
•
Config Port
: default value
• Status Port
: default value
• Control Port
: default value
Brightness
The brightness mode determines how the
brightness or intensity of the display is controlled.
• Automatic
: Use this option if the display is equipped with a light sensor. Dimming
values are determined by the light sensor and automatically adjusted according to
ambient light conditions. Values vary to reflect the information from the light sensor.
• Manual
: Use this option to manually enter the dimming values using the slider bar. The
brightness level remains at this value until it is adjusted. Moving the slider bar to the
right adjusts all color levels equally by the percentage indicated. For example, 100
percent means a full white image shows at the maximum light output of the display;
50 percent shows at 50 percent of the maximum light output capacity of the display.
Temperature
If the display is equipped with a temperature sensor, it may be necessary to enter an
offset. An offset compensates for environmental conditions such as a sensor mounted
too close to a heat source or in the shade. Such conditions will affect the accuracy of
the temperature reading by a specified amount (-9 °C to +9 °C). Enter an offset by typing
in a value in the
Offset
field or by moving the slider bar. The default offset is
0
.
Test Patterns
The
Test Patterns
drop-down list includes all test patterns that are available on the VIP.
Select one of these test patterns to trigger the VIP to play it.
Figure 39:
VIP-4000 Series