4.3 Troubleshooting 

This section lists potential problems with the display, indicates possible causes, and 
suggests corrective action. This list does not include every possible problem, but it 
does represent some of the more common situations that may occur. (Refer to the 
appropriate manual for a list of potential problems with add-on or separately 
mounted message centers. 
 

Symptom/ 

Condition 

Possible Cause 

Solution 

No displays in the 

sign will light 

 

Power incorrectly set up.

 

 

 

 

Addresses not set correctly.

 

 

Open display with host driver 

and check Power LED 

(Section 4.2). 

 

Check each driver to verify 

correct address settings 

(Section 3.2). 

Multiple line sign 

with all lines 

showing same 

prices 

 

Addresses not set 

correctly. 

 

Set up different address for 

each line of sign (Section 3.2). 

Digit will not light 

 

Black wire to digit broken. 

 

Poor contact at driver 

connection. 

 Driver 

malfunction. 

 Replace 

harness. 

 Clean 

contacts. 

 

 Replace 

driver. 

Segment or several 

LEDs will not light 

 Broken 

LEDs. 

 Driver 

failure. 

 

Broken wire between 

driver and digit. 

 

Poor contact at driver 

connector. 

 

Replace segment or digit. 

 Replace 

driver. 

 Replace 

harness. 

 

 

Clean contact or replace 

harness. 

Segment or digit 

stays lit 

 Driver 

failure. 

 

Short circuit on digit. 

 Replace 

driver. 

 Replace 

harness. 

Data appears in the 

wrong place on the 

sign 

 

Signal connections are 

not correct. 

 

Reconnect signal wiring to 

drivers (Section 3.2).  

Data appears on the 

wrong line of the 

display 

 

Incorrect address settings 

on drivers. 

 

Change addresses on drivers 

(Section 3.2). 

Display shows "E4". 

 

No Message Error: This 

code is shown when no 

messages are 

downloaded to the 

display. 

 

Download a new message to 

the display using the <

UPDATE 

DISPLAY

> key on the 

DataMaster 100 controller. 

 

 

Maintenance and Troubleshooting 

4-3 

 

 

Содержание DF-2300 Series

Страница 1: ...DF 2300 Series Flexible Drop in Model Installation and Operation Manual ED 17026 Rev 0 10 January 2007 331 32nd Ave PO Box 5128 Brookings SD 57006 Tel 605 697 4034 or 877 605 1113 Fax 605 697 4444 We...

Страница 2: ..._________ DataMaster Serial No __________________________________________ DAKTRONICS INC Copyright 2007 All rights reserved While every precaution has been taken in the preparation of this manual the...

Страница 3: ...3 3 2 Signal Connection 3 4 LED Drivers 3 4 Signal Wiring 3 4 Address Dip Switch Settings 3 4 Section 4 Maintenance and Troubleshooting 4 1 4 1 Component Location and Access 4 1 4 2 Diagnostics 4 2 4...

Страница 4: ...7 1 Replacement Parts List 7 1 7 2 Connecting the DM 100 to the Display 7 2 7 3 DataMaster Insert and Code 7 3 7 4 Petroleum Price Display Operation 7 3 Petroleum Price Display Startup 7 4 Petroleum...

Страница 5: ...Power Connection 3 3 Figure 8 Driver 3 4 Figure 9 Dip Switches 3 5 Figure 10 Back Access Options 4 1 Figure 11 Inside Views of Front and Back Panels 4 2 Figure 12 Driver Diagnostics 4 2 Figure 13 Digi...

Страница 6: ......

Страница 7: ...s display type is a flexible drop in model allowing the face to fit a curved sign The displays feature highly visible PanaView digits that are 10 13 or 22 tall DataMaster displays use light emitting d...

Страница 8: ...g Figure 3 This reference number includes the last set of digits and the letter preceding them The drawing in this example would be referred to as Drawing A 181218 Figure 3 Daktronics Drawing Label Th...

Страница 9: ...Drawing DF 2300 13 NA DI SHE FLEX Drawing B 281224 Shop Drawing DF 2300 22 NA DI SHE FLEX Drawing B 287545 The table below gives the size weight and power specifications for each display model Models...

Страница 10: ...angular opening in the sign face centered between the retainers Use the dimensions in the appropriate shop drawing or the previous chart as a reference for the size of the opening 3 Test fit the displ...

Страница 11: ...and ground from the main disconnect to the display driver power enclosure connecting the display ground to a ground rod at the sign location routing the control signal cable from the control location...

Страница 12: ...ion 2 to determine maximum power requirements for this model It is critical that the display circuit be fused at 15 A and that all conductors used must be designed to pass a 15 A current in normal ope...

Страница 13: ...requires the use of a lockable power disconnect within sight of or at the display The use of a disconnect also significantly protects the circuits against lightning damage Follow these guidelines for...

Страница 14: ...Drawings A 250728 for a complete listing of driver connector functions and wiring pin numbers Signal Wiring Signal wires are terminated with a telephone type RJ14 connector Route the cable from the ja...

Страница 15: ...ay to check that the displays are set up and working correctly The following items will be shown on the digit displays The second column explains the significance of each item Information shown on dis...

Страница 16: ......

Страница 17: ...s the components of these displays depending on the tasks that need to be accomplished Refer to Figure 10 Back panel removal The back panel may be taken off if the digits or driver need to be removed...

Страница 18: ...These LEDs can help pinpoint problems with driver set up or operation The LEDs give the following information Maintenance and Troubleshooting 4 2 LED Color Status DS1 Green Continuous light when driv...

Страница 19: ...on 3 2 Digit will not light Black wire to digit broken Poor contact at driver connection Driver malfunction Replace harness Clean contacts Replace driver Segment or several LEDs will not light Broken...

Страница 20: ......

Страница 21: ...r 14 pin 0P 1192 0256 Digit 10 7 segment green 14 pin 0P 1192 0312 Digit 7 9 10 red 0P 1192 0253 Digit 7 9 10 amber 0P 1192 0254 Digit 7 9 10 green 0P 1192 0355 Digit 13 7 segment red 14 pin 0P 1192 0...

Страница 22: ...and held assembly 0A 1110 0046 DataMaster 100 hand held controller 0A 1196 0088 DataMaster 100 outdoor wired installation kit 0A 1356 0002 DataMaster 100 indoor wired installation kit 0A 1356 0105 Dri...

Страница 23: ...Release the connector by squeezing together the locking tabs as the plug is pulled free 3 The digits are secured to the inside of the panel with fixed machine screws spacers and push nuts Remove the n...

Страница 24: ...rews and tighten the nuts 5 Reconnect the power signal connector Note This is a keyed connector and will attach in one way only Do not attempt to force the connection 6 Replace and secure the back pan...

Страница 25: ...part arrived b Fill out and attach the enclosed UPS shipping document c Ship the part to Daktronics 3 You will be billed for the replacement part immediately unless you have a qualifying service agre...

Страница 26: ...exchange Daktronics offers a Repair Return Program To send a part for repair follow these steps 1 Call your local Daktronics representative or the Daktronics Customer Call Center 877 605 1115 toll fre...

Страница 27: ...W 1267 c Indoor junction box 0A 1196 0099 for direct wired installations or Radio Interface junction box 0A 1279 0161 for wireless installations d Wallpack transformer T 1118 3 Mount the wall bracket...

Страница 28: ...etween the sign and the DM 100 6 2 Configuring the DM 100 for Gilbarco G Site Interface Preparation The DM 100 function must be set to GAS PRICE The current function of the DM 100 is displayed during...

Страница 29: ...this line This may be useful for configuring some lines of a price sign to receive manual price changes only 4 Select a price category to be displayed on each line of the sign and press MENU or ESC CL...

Страница 30: ...and press MENU or ESC CLEAR when finished The POS interface configuration is complete 6 4 Configuring the DM 100 for PAM 1000 Interface Preparation The DM 100 function must be set to GAS PRICE The cu...

Страница 31: ...P O S systems the system grade numbers are the same as the product numbers in the Ruby when setting prices in the Ruby the first product listed is system grade 1 Use the and keys to select a grade fo...

Страница 32: ...y is configured will automatically update when the price is changed in the POS system Attempting to manually edit prices that are configured for POS control will cause the following screen to appear T...

Страница 33: ...mber DM 100 can be configured to display petroleum price motel rates and time and temperature data Refer to Drawing B 256001 for information on possible control options and connection procedures Note...

Страница 34: ...in conduit where required This control option does not require the controller to be connected to a power outlet In this configuration the DataMaster 100 uses the sign as a power source To operate the...

Страница 35: ...Cut this to size and slide it into the DM 100 pocket Use this as a reference until a replacement is received To start the controller and use the insert to program information into the display driver...

Страница 36: ...e bottom line of the LCD during startup do nothing The controller will automatically default to previous Gas Price settings If a function other than GAS PRICE was shown on the bottom line of the LCD d...

Страница 37: ...ng the EDIT key during operation or by using the MENU key refer to Menu Items chart following this screen The following keys identify items to be edited L Current line number to be edited D CC Current...

Страница 38: ...D 13953 DataMaster Modem Installation Manual For additional information about the Display Status or the Set Time submenus refer to ED 13894 DataTime Radio Installation Manual This manual provides comp...

Страница 39: ...Press CLEAR at any time to exit the Display Status submenu LCD Screen Action DIM level xx 0 dim 63 bright Dimming mode Automatic Dim Level This is the intensity level of the display 0 is the dimmest...

Страница 40: ...ogrammed on the host MASC driver in the display Current Day Time This is the Day Time value set in the driver The time format used will be 24 hour Note To set the Day Time see the Set Time section of...

Страница 41: ...d Using the number keys enter the Time in the 12 hour or 24 hour format Press the down arrow key to modify the AM PM setting Note The flashing asterisk shows the current data being edited To save chan...

Страница 42: ...g is shown on the bottom line of the LCD LCD Screen Action DIMMING AUTOMATIC Press the down arrow key to toggle through dim settings Automatic The display automatically dims based on the light detecte...

Страница 43: ...must be connected to the display Press ENTER to accept this intensity If the manual dimming mode is selected this will be the new intensity for the display If the automatic dimming mode is selected th...

Страница 44: ......

Страница 45: ...ce on the display press and hold any button for five seconds When the sign is in Edit mode the decimal LEDs blink On the RC 50 each pair of buttons corresponds to a price line on the display Each line...

Страница 46: ......

Страница 47: ...Reference Drawing System Riser Diagram RC 100 DataMaster Drawing A 244838 Figure 21 RC 100 Controller The RC 100 controller can be configured to program petroleum price variances displayed on the LED...

Страница 48: ...for different displays To operate the RC 100 press any of the keys listed in the following petroleum price sections RC 100 Controller Operation The Petroleum Price Controller LCD display will default...

Страница 49: ...the display can detect the level of ambient light at the display location and dim the sign s LEDs accordingly This function is known as automatic dimming When the manual dimming function is selected t...

Страница 50: ...rent intensity of the display Note The DataMaster must be connected to the display Press ENTER to accept this intensity If manual dimming mode is selected this will be the new intensity for the displa...

Страница 51: ...acket to which it is mounted A collection of circuit boards working as a single unit may also carry an assembly label W _ _ _ _ denotes a wire or cable Cables may also carry the assembly numbering for...

Страница 52: ......

Страница 53: ......

Страница 54: ......

Страница 55: ......

Страница 56: ......

Страница 57: ......

Страница 58: ......

Страница 59: ......

Страница 60: ......

Отзывы: