DAKTRONICS AQUATICS MAINTENANCE CHECKLIST 

 

DD3691471  072017 

201 Daktronics Drive  PO Box 5128  Brookings, SD 57006-5128 

 

800-325-8766  605-692-0200  fax 605-697-4700 

www.daktronics.com  email [email protected] 

 

 

 

Use this checklist to ensure your Daktronics Aquatic Systems is operating properly and looking 

as good as possible. We recommend completing these checks every six months, or whenever 

you suspect an issue with your display. In most circumstances, the owner or operator of the 

display should be able to complete this checklist. For additional information and 

troubleshooting resources, see the appropriate manual for your display. 

 

 

Checklist Task 

Key Points 

 

    

 

    

 

   

 

OmniSport 2000 

o

 

Visually inspect the OmniSport for damage/corrosion. (indicators, switches, 

knobs, and connections). 

o

 

Ensure keypad buttons are all functional. 

o

 

Verify that thermal paper is installed in printer location and  

feeds/prints correctly. 

o

 

Power up OmniSport console to verify firmware is up to date  

(update if needed). 

 

Must be newer than 8.3.27 to update in the field. 

o

 

Perform Mock swim race after completing checklist to verify all inputs and 

outputs are working (including scoreboard/RTD data). 

 

 

OmniSport 2000 Manual=ED-13312

 

 

   

  

 

 

 

On-deck Equipment  

(lane modules) 

o

 

Visually inspect lane modules for damage/corrosion. (connections, 

connector, and cable). 

o

 

If equipment shows signs of corrosion, train customer (if available) proper 

cleaning of lane modules using the brass brush (TH-1024/TH-1025) and 

silicone grease (LU-1002). 

 

 

How to Test a Daktronics Lane Module

 

 

      

 

 

 

 

In-deck Equipment 

(deck plates) 

o

 

Visually inspect all deck plates for damage/corrosion.  

(connections, connector, and cable). 

o

 

If equipment shows signs of corrosion, train customer (if available) proper 

cleaning of lane modules using the brass brush (TH-1024/TH-1025) and 

silicone grease (LU-1002). 

OmniSport 2000 Manual=ED-13312

 

 

     

  

 

 

Содержание Aquatics

Страница 1: ... o Verify that thermal paper is installed in printer location and feeds prints correctly o Power up OmniSport console to verify firmware is up to date update if needed Must be newer than 8 3 27 to update in the field o Perform Mock swim race after completing checklist to verify all inputs and outputs are working including scoreboard RTD data OmniSport 2000 Manual ED 13312 On deck Equipment lane mo...

Страница 2: ...hes knobs cabling and connections o Testing 1 Test for charger functionality by connecting to the HS 200 Charging LED should light when plugged in 2 Ensure microphone is connected to the horn start assembly Wireless models ensure belt pack has a new battery and matches the wireless channel set on the HS 200 base assembly and has the antenna mounted on the base unit 3 Set volume controls to desired...

Страница 3: ...and when pressing on the pad it should create a shorted connection 4 If the pad passes the try test it can be put in the water to complete the we test by measuring for DC voltage Wet Test 1 1 Place all touchpads into the water and connect to their lane connections 2 Turn on the OmniSport 2000 and go into swimming mode 3 Press MENU 5 2 and go into the test mode 4 Use your hand or a swimmer to tap t...

Страница 4: ...nto the lane harness and the OmniSport connected and setup in Swimming mode 3 Place your hand flat on the RTOP and hold for two seconds 4 Remove you hand quickly and the red LED will turn solid for 1 second then return back to a flashing ready state 5 The RTOP time should also be able to be captured on the OmniSport printout as long as settings event are configured correctly Relay Take off Platfor...

Страница 5: ...al cable adapter on the Pro Dive computer o Verify communication between devices May need to change com port value in Pro Dive or set to UDP o Tip When using serial connections with an Ethernet OmniSport the network port must be disabled to allow serial communications MENU 4 7 7 NETWORK PRO OFF will allow you to shut off the Network Pro option Detailed Instructions ED 16444 Hy Tek Meet Manager o V...

Страница 6: ...setups use Generic Serial for Alternative configurations CTS Timer o Verify judge console firmware is up to date 3 0 or higher JC 100 and RC 100 options o Verify base station firmware is up to date if using wireless judge consoles 3 0 or higher o Verify the base station function Function setting should be set to a 6 on version 3 0 and higher Function 1 for earlier versions o Verify the correct 900...

Отзывы: