8
Content switched
between display
sections
1. Check the signal interconnect cables between
the display sections because they may be
switched. Port A should be connected to Port
A. Port B should be connected to Port B.
2.
Check the fiber cables coming from the DMP
because they may be switched.
Scattered or out
of order content
1. The SATA cable and redundant SATA
cable from the PLR to the modules may be
switched.
2. Call Daktronics help desk to verify the
translation table is correct.
Area of content
mixed up -
module ID out of
order
1. Verify the SATA cable path in that area is
correct by comparing it to the display signal
drawing. If not, correct the signal path.
1 module out
1. Ensure the SATA and power cables to the
module are connected and secure.
2. A SATA cable may be damaged, replace
both SATA cables to the module to see if this
addresses the issue.
3. It is likely a bad module. Swap the module
with a replacement module and verify that the
new module functions correctly.
2 modules out
1. Check the status indicators on the back of the
modules. If the indicators are off, check the
power indicator on the power supply for the
affected modules. If the power supply indicator
is off and there is power connected to the
power supply, replace the power supply.
2. If there is power to the power supply and
the modules, check the SATA cables to the
modules. It is possible the SATA cables at the
beginning and end of the affected modules are
disconnected or bad.
Display Troubleshooting