MAN 650314:D
14
SETTING UP THE CONTROL BOX
Below is the list of setup menus. You must have SW1 wired to enter setup, SW2 will be
used in some menus as well; descriptions of each menu are below. Pay close attention to
Setup menus and options as incorrect settings will cause faulty readings on the displays.
Main Menu
Sub Menu
Description____________________
SPEED
SENDER
(
normal
,
bus
)
Select sensor type
AUTO
Auto calibrate speed
ADJUST
Adjust the speed calibration
SERVICE
(
OFF
,
500
–
7500
)
Select the service countdown
OUTPUT
(
2k ppm
,
4k PPm
)
Select output speed signal PPM setting
DONE
Exit setup menu
TACH
ENGINE
(
bus
,
1
–
16
)
Set engine cylinder count
UPDATE
(
slow
,
mid
,
fast
)
Set RPM update rate
WARN
(
2200
–
14800
)
Set RPM shift warning point
SIGNAL
(
5V LOw
,
12V HIGH
)
Select RPM signal voltage level
DONE
Exit setup menu
VOLT
WARNING
(
LOW 10.0
–
13.1
)
Set low volt warning point
DONE
Exit setup menu
WATER
SENDER
(
DD F
,
DD C
,
BUS F
,
BUS C
)
Select sensor type
WARNING
(
150-300F / 65 -148c
)
Set high temp warning point
TEST
Display sensor ohm reading
DONE
Exit setup menu
OIL
WARN
(
LOW
5
–
36
)
Set low pressure warning point
TEST
Display sensor voltage reading
DONE
Exit setup menu
FUEL
SENDER
(
SW 33
,
CUSTOM
,
Select sensor type
GM 30
,
GM 90
,
GM 250
,
F 10
,
F 150
,
V 180
)
CUSTOM
Calibrate custom fuel sensor
TEST
Display sensor ohm reading
DONE
Exit setup menu
LIGHTING
DIM LEVEL
(
ADJUST 0-31
)
Change preset night dimming
DAY LEVEL
(
ADJUST 0-32
)
Change day time backlighting
DONE
Exit setup menu
BIM
SCAN
Check/scan for connected modules
SETUP
Enter setup (only when modules present)
DONE
Exit setup menu
DISPLAYS
INDICATORS
Enable indicators on face and LCD
(
LIGHT ONLY
,
LIGHT+LCD
)
LOCATION
(
1
,
2
,
1+2
,
OFF
)
Select display location
DONE
Exit setup menu
Содержание VHX-78C-MC
Страница 42: ...MAN 650314 D 34...