background image

POWER WINDOW WIRING 

 

TO CONSTANT-ON

FUSED +12V

NOT INCLUDED

POWER WINDOW

SWITCH

SPLICE

YELLOW

REGULATOR AND SWITCH

CONSTANT-ON

FUSED +12V

DO NOT USE

DO NOT USE

FUSED +12V

TO CONSTANT-ON

GROUND

CHASSIS

BLACK

RED

required for this style
of wiring connection

Special regulator or
an additional relay module

CONSTANT-ON

FUSED +12V

GRAY

WHITE

PINK

ORANGE

WI

ND

O

W

 RE

G

U

L

A

TO

R

T

O PASSEN

GER

 SI

D

E

BLUE

GREEN

RED

DUAL

RELAY

PACK

DUAL

PACK

RELAY

BLUE

RED

GREEN

WHITE

BROWN

GREEN

BLUE

PURPLE

small wire

small wire

CONNECT TO

small wire

wire

small

PURPLE

BLUE

GREEN

BROWN

WHITE

GROUND

SEALED
SWITCH

BROWN

GROUND

Driver's Window 
Emergency Entry

Switch

Figure 5.  Connection to power window regulators with a three wire 12 volt switch. 

 
 

CONSTANT-ON

NOT GROUND-AT-REST

4-WIRE or 3-WIRE

SWITCH

FUSED +12V

IS NO LONGER CONNECTED.
CONNECTING A +12V WIRE
TO THE SWITCH WILL
DAMAGE THE REMOTE
CONTROL UNIT!

DO NOT CONNECT

CHASSIS
GROUND

POWER WIRES

NOTE THAT +12V WIRE
ON POWER WINDOW SWITCH

BLACK

BLUE

FUSED +12V

BLUE

BLACK

GROUND

CHASSIS

TO CONSTANT-ON

REGULATOR AND SWITCH

NOT INCLUDED

WINDOW MOTOR WIRES

wire

ORANGE

DUAL

RELAY

PACK

GREEN

WHITE

BROWN

BLUE

RED

GREEN

small

wire

small

BLACK

PURPLE

CHASSIS
GROUND

BLUE

CONSTANT-ON

FUSED +12V

GRAY

CONNECT TO

PINK

WHITE

RED

W

IND

OW

 RE

GUL

A

TOR

T

O

 PA

SS

EN

GER

 S

ID

E

PACK

RELAY

DUAL

RED

WHITE

BROWN

GREEN

BLUE

PURPLE

SEALED
SWITCH

Driver's Window 
Emergency Entry
Switch

BROWN

GROUND

Figure 6.  Connection to power windows with 4-wire switch (not center position grounding). 

 

Содержание CMD-9000

Страница 1: ...he accidental opening of a door during vehicle operation With the ignition on the only functions that are allowed to work are the control of the power windows An emergency release switch can be concealed on the underside of the vehicle to roll the driver s window down should the door ever be closed with the transmitter on the inside and you on the outside ADDITIONAL TRANSMITTERS The transmitters s...

Страница 2: ...latch actuator PURPLE trunk release latch actuator WHITE RED trunk lift motor raise relay WHITE BLUE trunk lift motor lower relay ORANGE passenger s window up relay PINK passenger s window down relay WHITE driver s window up relay GRAY driver s window down relay WHITE GREEN auxiliary relay output The blue green and purple wires are connected to internal relays and can feed 12 volts out at up to 10...

Страница 3: ...Y 12 VOLT MOTOR OR SOLENOID MAY BE USED GREEN BLUE BLUE GREEN GREEN BLUE 10 amp max 10 amp max 10 amp max TO CHANGE THE PDR 1 FROM PULL TO PUSH SWITCH THE BLUE AND GREEN WIRES Figure 1 Door and trunk latch wiring diagram MOMENTARY POWER SWITCH FUSED 12 VOLTS ACTUATOR OUTPUT WIRE FROM REMOTE SYSTEM WIRE HARNESS CHASSIS GROUND DOOR OR TRUNK LATCH ACTUATOR Figure 2 Wiring to control actuator with the...

Страница 4: ...ORANGE RED WINDOW REGULATOR TO PASSENGER SIDE DUAL RELAY PACK BLUE GREEN PURPLE BLUE GREEN BROWN WHITE DUAL RELAY PACK MANUFACTURER small wire small wire small wire wire small BROWN Driver s Window Emergency Entry Switch GROUND SEALED SWITCH GROUND AT REST Switch contact positions vary with style Figure 4 Connection to Specialty Downs Balls GM and other power window regulators using a 5 wire or ce...

Страница 5: ...e 5 Connection to power window regulators with a three wire 12 volt switch CONSTANT ON NOT GROUND AT REST 4 WIRE or 3 WIRE SWITCH FUSED 12V IS NO LONGER CONNECTED CONNECTING A 12V WIRE TO THE SWITCH WILL DAMAGE THE REMOTE CONTROL UNIT DO NOT CONNECT CHASSIS GROUND POWER WIRES NOTE THAT 12V WIRE ON POWER WINDOW SWITCH BLACK BLUE FUSED 12V BLUE BLACK GROUND CHASSIS TO CONSTANT ON REGULATOR AND SWITC...

Страница 6: ...act positions vary with style MANUFACTURER VARY DEPENDING ON TRUNK LIFT MAY WIRE COLORS COMING FROM Figure 7 Connection to power trunk lift motor SINGLE RELAY WIRING FOR AUXILIARY OUTPUTS The single relay shown is not included in the base kit These are available from Dakota Digital RLY 1 however any 12 volt automotive relay will work BLACK BLUE 86 87 85 30 GREEN SWITCHED OUTPUT CONSTANT ON FUSED 1...

Страница 7: ... LOCK SYSTEM PURPLE WHITE BLUE GREEN BROWN PACK RELAY DUAL GREEN RED BLUE CHASSIS GROUND CONSTANT ON FUSED 12V RED BLACK WHITE RED WHITE BLUE small wire small wire Figure 9 Connection to power door locks with 3 wire 12 volt switch LOCK SYSTEM FACTORY DOOR TO CHASSIS DO NOT CONNECT SWITCH DOOR LOCK GND 12V GND GROUND CHASSIS GROUND CONSTANT ON FUSED 12V PACK WHITE GREEN BROWN WHITE RED FUSED 12V GR...

Страница 8: ...kota Digital s PDR 2 an external relay should be used for powering the solenoids on outputs 3 and 4 see figure 3 FUSED 12V small wire BLUE small wire GREEN RED DO NOT CONNECT DO NOT CONNECT ACTIVATED WHEN BUTTON 1 IS PRESSED ACTIVATED WHEN BUTTON 2 IS PRESSED TO DOOR LATCH RELEASE TO DOOR LATCH RELEASE FUSED 12V CONSTANT ON CHASSIS RELAY BROWN WHITE GREEN PACK BLUE PURPLE GROUND BLACK DUAL CONNECT...

Страница 9: ...volts for approximately one second Button 5 Trunk latch application Pressing button 5 will activate the third internal relay for about one second The white w blue and white w red wires should not be used Button 5 Trunk lift lock unlock or similar The first time the button is pressed it will raise the trunk or unlock doors until it is released The next time it is pressed it will lower the trunk or ...

Страница 10: ...or each button Press and release button 5 and then press one of the other buttons for the functions listed below Pressing button 5 and then button 1 will activate an external relay to raise a trunk lift unlock doors or any other function It will remain on until the button is released Pressing button 5 and then button 2 will activate an external relay to lower a trunk lift lock doors or any other f...

Страница 11: ...nd position 4 Replace the battery with a new 12 volt type GP23A battery which is available at most electronic stores Radio Shack battery stores etc 5 Carefully replace the top cover and refasten the screw INSTRUCTIONS FOR TESTING AND PROGRAMMING TRANSMITTERS All of the transmitters to be programmed into the system should be available This sequence will erase any previously programmed transmitters ...

Страница 12: ...ETIME OF THE CAR IN WHICH IT WAS ORIGINALLY INSTALLED such defect s will be repaired or replaced at the Company s option without charge for parts or labor directly related to repairs of the defect s To obtain repair or replacement within the terms of this Warranty the product is to be delivered with proof of warranty coverage e g dated bill of sale specification of defects transportation prepaid t...

Отзывы: