background image

Dakota Computer Solutions  

  1579 Lexington Road  

  Green Oaks, IL 60048  

  Tel: 847-816-1337  

  Fax: 847-816-4558

3

VGA

Keyboard

Mouse

Front View of Remote Unit

Power

Supply

Power

Interconnect

Remote Unit

Peak

Eq

Rear View of Remote Unit

VGA

Keyboard

Mouse

Front View of Local Unit

Rear View of Local Unit

Interconnect

Local Unit

Figure 1.  Connecting the VoyagerUTP.

Voyager UTP

Remote Unit

Remote Unit

Remote Unit

Remote Unit

EQ

JP 3

JP 3

JP 3

JP 3

JP 4

JP 4

JP 4

JP 4

Cable Length Jumpers

Cable Length Jumpers

Cable Length Jumpers

Cable Length Jumpers

JP 5

JP 5

JP 5

JP 5

MOUSE

MONITOR

POWER

RJ45

KEYBOARD

PEAK

Position A

Cable Length

100 - 200 Meters

Position B

Cable Length

200 - 300 Meters

Default Position - No Jumpers

Cable Length

 0 - 100 Meters

All three jumper sets must be set to the same position.

All three jumper sets must be set to the same position.

All three jumper sets must be set to the same position.

All three jumper sets must be set to the same position.

TM

Figure 2.  Remote Unit PCB - Cable length jumpers.

QUICK SETUP SYSTEM GUIDE

Содержание VoyagerUTP

Страница 1: ...79 Lexington Road Green Oaks IL 60048 Tel 847 816 1337 Fax 847 816 4558 V Vo oy ya ag ge er rU U U U U U U UT T T T T T T TP P P P P P P P T TM M Keyboard Monitor Mouse Extender Installation and Operation Manual www dakota us com ...

Страница 2: ...UNTRIES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU IF THIS PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED ABOVE YOUR SOLE REMEDY SHALL BE REPLACEMENT OR REPAIR AS PROVIDED ABOVE IN NO EVENT WILL DAKOTA COMPUTER SOLUTIONS BE LIABLE TO YOU FOR ANY DAMAGES INCLUDING ANY LOST PROFITS LOST SAVINGS OR OTHER INCIDENTAL OR CONSEQUENTIAL D...

Страница 3: ...ystems no software is required Just connect the units up as described and you are ready to work Complete keyboard and PS 2 mouse emulation ensuring that your computer will not lock up due to loss of keyboard and mouse connection Your PC will boot even if the remote end of the link is not powered or the keyboard and or mouse are disconnected Compatibility To operate in various environments and with...

Страница 4: ... to Remote Unit connection cable is not supplied if you do not have suitable CAT 5 UTP or STP cable fitted at your site please consult your dealer The Local and Remote Units are connected by industry standard structured cabling Category 5 UTP STP 4 pair terminated with RJ45 connectors The cable used should be solid trunk cable Stranded patch cable will give poor results over longer distances The c...

Страница 5: ... EQ JP 3 JP 3 JP 3 JP 3 JP 4 JP 4 JP 4 JP 4 Cable Length Jumpers Cable Length Jumpers Cable Length Jumpers Cable Length Jumpers JP 5 JP 5 JP 5 JP 5 MOUSE MONITOR POWER RJ45 KEYBOARD PEAK Position A Cable Length 100 200 Meters Position B Cable Length 200 300 Meters Default Position No Jumpers Cable Length 0 100 Meters All three jumper sets must be set to the same position All three jumper sets must...

Страница 6: ...ting the Cable Length Jumpers The Remote Unit contains video equalization circuitry which compensates for loss in image quality experienced when driving over long cables To set the correct level of equalization there are three jumpers on the circuit board used to select an adjustment range appropriate to the cable length these only need to be set once and two rotary controls on the front panel to ...

Страница 7: ...smearing on the right hand edge of large horizontal objects such as title bars The degradation becomes more noticeable as cable length increases 3 Look at a point on the monitor where the smearing is evident Now rotate the EQ control clockwise until the smearing disappears and the edge becomes very bright and too sharp At this point and beyond the video is over compensated 4 Rotate the EQ control ...

Страница 8: ... UTP allows recovery of the mouse should it ever go out of sync mouse pointer jumps over the screen Use the following procedure to recover the mouse 1 Press and release the Scroll Lock key twice on local console to reset the keyboard and mouse 2 Check if the mouse is now operating correctly If the mouse is still erratic issue the following Null mouse command to re synchronize the mouse 3 Press and...

Страница 9: ...board The Scroll Lock LED will now light on both local and remote keyboards Press Scroll Lock again to re enable the remote console Scroll Lock will also re initialize the local keyboard and mouse The local console is active on power up When the remote console is powered up it may take up to 15 seconds to be initialized This will result in a blank screen Jumper JP1 normally off in the Remote Unit ...

Страница 10: ...s Scroll Lock on the keyboard to reset the mouse b Cable is loose re seat mouse cable and press Scroll Lock a number of times c Wrong cable plugged in keyboard and mouse cables reversed d Try a different model of mouse e Power cycle the remote unit The system does not detect a PS 2 mouse or the application cannot find the mouse a Wrong cable plugged in keyboard and mouse cables reversed on Local U...

Страница 11: ...or the Local Unit A constant vertical wobble appears down the screen interference a The interconnection cable could be located too close to a source of very strong electrical interference re route cabling if possible b If interference is from strong signals from a nearby broadcast transmitter a beat pattern will appear Change the vertical refresh rate of video card slightly such as from 65Hz to 70...

Страница 12: ...better choice in electrically noisy environments When using UTP what is the best way to ensure the system does not suffer from any interference This product is designed to withstand high levels of interference while using Cat 5 cable over long distances To further reduce the potential for interference consider the following a Ensure that the computer and remote monitor are both connected to the sa...

Страница 13: ...ble to solve your problem directly over the telephone If we cannot solve your problem on the telephone or determine that the fault is in the unit we will issue a Return Material Authorization RMA number that must appear on the outside of all returned products The unit should be double packed in the original container insured and shipped to the address given to you by our Technical Support represen...

Страница 14: ...c Polarity preserved Keyboard Compatibility PC AT and PS 2 Mouse Compatibility Standard PS 2 two Button Logitech PS 2 three Button and Microsoft Intellimouse Console Lockout Time Period 15 seconds Dual version only VoyagerUTP Compatible Products Description Part No Dakota Scout KVM Switch 2 4 8 Ports PC only Vista Native KVM Switch 2 4 8 Ports PC only Vista Native KVM with OSD 4 8 Ports PC only Se...

Отзывы: