background image

Upgraded for e-Nova applications

Содержание SH710AX

Страница 1: ...Upgraded for e Nova applications...

Страница 2: ...eal test 159 8 Maintenance 160 8 1 Fault indications 160 8 2 Changing the battery 160 9 DAITEM guarantee and extension conditions 162 10 Technical data 163 1 Introduction Recommendations The device mu...

Страница 3: ...0 min Outputs 3 to 8 6 low power outputs toggle switch ON OFF mode 1 3 s pulse mode 2 5 s pulse mode timer for 5 durations 10 s 90 s 3 min 15 min 30 min NO C NC It is controlled by the control panel i...

Страница 4: ...open the receiver Coller sur certif SH710AX A1250A04823 SH710AX A1250A04823 Coller sur certif SH710AX A1250A04823 SH710AX A1250A04823 2 Remove the pre cut part of the sticker and stick it to the guar...

Страница 5: ...shes red every 2 s if the magnet based anti removal system has not been properly installed see chapter 5 3 Fixing the device in place Electrical shock hazard OR IMPORTANT The power supply used must be...

Страница 6: ...panel must be in installation mode The receiver is in installation mode when powered Refer to the installation manual for the control panel Briefly press the receiver test button Press and hold the Of...

Страница 7: ...button on the remote control or keypad in installation mode or the pushbutton on the pendant or the Test button on the detector or the 0 programming button on the smoke detector until the receiver re...

Страница 8: ...4 Single or confirmed intrusion NO NC 1 3 s pulse mode NO C NC NO C contact closes when single or confirmed intrusion signal received from control panel Output Description Contact in rest position Ope...

Страница 9: ...Single or confirmed intrusion group 6 10 Single or confirmed intrusion group 7 11 Single or confirmed intrusion group 8 12 Alert 13 Silent alarm 14 Fire alarm 16 GSM or PSTN telephone line anti tampe...

Страница 10: ...triggered 1 Proceed as follows using the control panel keypad 2 Wire as shown Output used 2 Timer 90 s receiver n 1 All alarms channel Coller sur certif SH710AX A1250A04823 SH710AX A1250A04823 Output...

Страница 11: ...ceiver is powered via the Bandit system 1 Output 1 is factory programmed for Disarming Total arming If this is not the case proceed as follows using the control panel keypad Output used 1 On Off recei...

Страница 12: ...e Rouge Blanc Vert Bleu Orange Noir Connecteur 5 points pour t l commande Red jump PaninV GrdinV F2 F3 ON ON 1 1 2 2 3 3 ON 1 2 3 4 Bloc A Bloc B Bloc C 500mA AlinV daeR npn Bouton Reset teseR npn L...

Страница 13: ...r 9 15 min timer 10 30 min timer IMPORTANT before setting the receiver parameters recognition programming must be performed see 3 2 Programming a product to be recognised by the receiver 1 For operati...

Страница 14: ...Press ON on the remote control until the receiver issues a beep to confirm Operation 1 Press ON on the remote control Press OFF on the remote control device switched on device switched off about 5 s...

Страница 15: ...ns supply with protection 12 V DC supply 2 Wire as follows A beep can be issued to indicate each change in system operating status To activate or deactivate this feature use the control panel keypad t...

Страница 16: ...activation when the PSTN line or GSM connection is cut 0 disabled factory 1 enabled receiver n The receiver monitors availability of the radio links If these are purposefully tampered with the receive...

Страница 17: ...rameter settings The receiver can be installed inside outside but in a location sheltered from the weather making sure there is a distance of at least 2 metres between each product except between two...

Страница 18: ...confirm SH710AX A1250A04823 beeep beep test device X 5 2 2 Testing other products 2 Check that the corresponding programmed output responds to the receiver or or one of the buttons on the remote cont...

Страница 19: ...points and drill the holes using an appropriately sized drill bit Pozidriv 2 3 Remove the washer insert it and fix the bracket in place using suitable plugs and screws 4 Take the anti removal magnet d...

Страница 20: ...8 mm diameter drill bit Hole 8 mm x 34 mm 7 Hook the base on to the fixing bracket 6 A Remove the anti removal magnet drilling template using a flat headed screwdriver B Take the magnet and the plug...

Страница 21: ...mm max remove the grommets and use a cross headed screwdriver to put a hole in them big enough to accommodate the wire diameter C Connect the wires as required B Cut the cables to the required length...

Страница 22: ...tor that can be connected to the terminal blocks is outputs 1 and 2 flexible or rigid cables 2 5 mm2 or 2 x 1 5 mm2 outputs 3 to 8 1 mm2 flexible or rigid cables earthing connection terminal block fle...

Страница 23: ...over and tighten the 4 screws 1 Switch the system to user mode using the control panel keypad to enter 2 Put the control panel cover back 6 Switching to user mode IMPORTANT if the control panel issues...

Страница 24: ...the receiver as it issues 3 short beeps Example if the receiver control panel radio link is lost the control panel issues the voice message 8 Maintenance 8 1 Fault indications To change the battery 8...

Страница 25: ...be replaced with the same type of pack with the same technical characteristics i e 2 x 3 6 V 17 Ah We advise you to use the DAITEM MPU01X battery available in the catalogue in order to guarantee indiv...

Страница 26: ...to replace defective products with an identical or equivalent product within the guarantee period All products exchanged under guarantee benefit from the remaining guarantee period of the original pro...

Страница 27: ...000 W 12 V electronic power supply 1500 W compact fluorescent built in electronic ballast 400 W semi separate power supply ferromagnetic ballast 360 W 4 possible operating modes toggle switch On Off p...

Страница 28: ...is product can be used in all EU EEA Countries and Switzerland Crolles 07 01 2013 Signature Patrick Bernard Research Development Manager Product reference SH710AX EN 300 220 2 V2 1 2 X EN 300 330 2 V1...

Отзывы: