GB
107
3.
Check the sequences:
• recorded by reading the microSD card (see User guide),
• transmitted via the standalone dialler (or by the control panel fitted
with a transmission module).
4.
If the optical field test does not work:
• check there are no obstacles in the way of the detection zone,
• loosen the screw and tightening washer in order modify detector
orientation.
5.
Put the control panel back in user mode using the keypad to enter:
6.
Perform a real test.
installer code
“beep,
disarmed”
7. Maintenance
7.1 Fault indications
The control panel constantly monitors detector status. Depending on the
fault, it issues a voice message when the system is disarmed or armed as
indicated in the table below:
7.2 Changing the battery
The control panel indicates a detector battery fault by
issuing the voice message
“fault, voltage, detector X”
.
To check whether the detector lithium power pack is faulty,
press the detector test button.
IMPORTANT: if the red LED does not light up when the test
button is pressed, the lithium power pack needs replacing.
Message issued by the control panel
Cause
“beep, fault, detector X”
no microSD card inserted or
card not recognised or faulty(*)
“beep, fault, tamper, detector X”
detector not properly clipped
on to base
“beep, fault, voltage, detector X”
lithium battery low
“beep fault, radio link, detector X”
radio link between detector
and control panel faulty
(*) check there is a micro SD card present and whether it is properly inserted.