4. Parameter-setting
IMPORTANT: detector parameter-setting must only be performed with
the detector cover open.
4.1 Setting the parameters of detector SH195AX
Function
description
Parameter
n°
Parameter
value
Characteristics
Detection
sensitivity
1
1
Beam crossed a first time: not recommended
2
Beam crossed a second time (factory
configuration):
recommended
Test LED
lighting (1)
2
1
Deactivated (factory configuration)
2
Activated
Alarm level
4
1
Intrusion (factory configuration)
2
Prealarm
3
Deterrence
4
Warning
Image sequence
on request (2)
6
1
Authorisation activated (factory configuration)
2
Authorisation deactivated
Above freezing
temperature
7
1
Detection deactivated (factory configuration)
2
Detection activated
4.2 Setting the parameters of detector SH196AX
Function
description
Parameter
n°
Parameter
value
Characteristics
Test LED
lighting (1)
2
1
Deactivated (factory configuration)
2
Activated
Sensitivity level
setting
3
1
Level 1: standard sensitivity
(factory configuration)
2
Level 2: average sensitivity
3
Level 3: high sensitivity
4
Level 4: maximum sensitivity
Alarm level
4
1
Intrusion (factory configuration)
2
Prealarm
3
Deterrence
4
Warning
Image sequence
on request (2)
6
1
Authorisation activated (factory configuration)
2
Authorisation deactivated
Above freezing
temperature
7
1
Detection deactivated (factory configuration)
2
Detection activated
(1) The infrared detector has a test mode for testing the detection zone:
• press the test button and the detector switches to test mode for 90 seconds,
• each detection is indicated by the LED lighting up.
(2) Image transmission request via Daitem user Portal (when no intrusion has occurred).