Step V: Install bulkhead and power line: Firstly, plug the installing holes below the left and right upright poles
and the meter head with 6 bulkhead; finally, connect the power line with one-piece power switch of the
treadmill (note: guarantee the power line is off before connecting the power line, so as to avoid personal
injury), as shown in the figure below:

Step VI: Carefully check if each part of the treadmill is tightened. Run the treadmill at the slow speed and check
if the each part of the running belt is flexibly rotated and whether the tightness of the running belt is proper. As
for the running belt, no offset and sliding will prevail (see “Daily maintenance of powered treadmill”). Move the
treadmill to the proper position and then use it after the check is completed.

VI. Display and function operation of electronic meter

1. Introduction on operating interface of electronic meter

Содержание GT5Ds

Страница 1: ...GT5Ds DC Commercial Motorized Treadmill...

Страница 2: ...eadmill and ensure your safety it is forbidden for overweighed beyond the weight limit persons to use the treadmill and for two or more persons to use one treadmill simultaneously 6 Please do not walk...

Страница 3: ...Floor area 200 86 150cm Effective usable floor area 146 52cm Features 3000W DC motor Double safety protection functions with both emergency stop and soft stop PU handrail Multi windows LED display Pr...

Страница 4: ...n Safety switch Right armrest Right upright pole Upper protective cover Upper edge strip Running belt Right regulating box Treadmill frame Left regulating box Edge strip at left side Erector Left upri...

Страница 5: ...roduct explosion diagram 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 40 41 42 43 44 45 46 47 48 49 50 51 54 55 57 58 59 60 61 62 64 32 52 63 3...

Страница 6: ...gonal screw 1 15 Edge strip at right side 1 47 DC motor base 1 16 Right regulating box 1 48 Motor cushion 4 17 Left regulating box 1 49 M10X40 hexagon socket pan head screw 1 18 Universal foot pad 2 5...

Страница 7: ...trol line in the right upright pole with that at the lower right of the meter head secondly insert the meter head into the left and right upright poles finally lock the meter head on the left and righ...

Страница 8: ...e figure below Step VI Carefully check if each part of the treadmill is tightened Run the treadmill at the slow speed and check if the each part of the running belt is flexibly rotated and whether the...

Страница 9: ...hen it counts down to 0 the treadmill steadily slows down stops operation and displays End It enters into standby state when it fully stops operation for 5 seconds 2 4 Speed Window Displays the curren...

Страница 10: ...ncline Incline Standby state used to adjust the set value It is used to adjust the slope in the running state and its adjustment amplitude value is 1 segment time When it is continuously pressed and h...

Страница 11: ...stop key to stop the treadmill 4 4 Built in programs Press program switch key select any one of built in programs of P01 P12 At this time the distance calorie window displays program numbers P01 P12...

Страница 12: ...am key in standby state until the user defined program U01 U03 you want to run is reached and press the start key after the running time is set Pressing the start button can also start immediately aft...

Страница 13: ...or female and provides the basis for people to adjust their weight together with other health indicators The ideal FAT should be between 20 and 24 If it is lower than 19 it means too thin If it is bet...

Страница 14: ...to the corresponding position of electronic meter 1 2 Before the powering inspect whether the power ground wire is well grounded and pull the running belt with hands to check whether it can run flexib...

Страница 15: ...umber of sparks so the treadmill should be placed at a drafty place and kept away from explosives 2 3 When the treadmill is used ensure its fore and rear feet reliably contact the ground If the ground...

Страница 16: ...with the special lubricant The lubrication should not be excessive It is recommended that a 30ml bottle of special lubricating oil for the treadmill should be used for ten times 2 3 Lubricating metho...

Страница 17: ...tributed to following reasons 5 1 The treadmill body is placed unevenly 5 2 While exercising on the treadmill the user fails to run on the central position of the running belt 5 3 The strength of user...

Страница 18: ...l cannot be received by the drive E13 communication fault the drive signal cannot be received by the Electronic meter A The signal lines of the electronic meter is not well plugged or poor connection...

Страница 19: ...orth the strength The breath should be coordinating with the actions In case of short breath stop exercising immediately Frequency The training for the same muscle should be carried out at the interva...