Wiring Diagrams
SiENBE34-703
202
Appendix
2. Wiring Diagrams
2.1 Outdoor Unit
RXYSQ4 / 5 / 6P7Y1B
Notes
1.
This wir
ing diag
ram is applied only to the outdoor unit.
2.
:Field wir
ing.
3.
:T
er
minal str
ip
: Mo
v
a
b
le connector
,
: Fix
ed connector
: T
e
rm
inal
: Protectiv
e ear
th (Scre
w)
: Noiseless ear
th
4.
When using the option adapter
, ref
er to the installation man
ual.
5.
Ref
er to
“Oper
ation caution label”
(on bac
k of front plate) ho
w to use BS1~5 and DS1 • 2 s
witch .
6.
When oper
ating, don’t shor
tcircuit f
or protection de
vice (S1PH).
7.
Colors RED:Red BLU:Blue
WHT
:White
YL
W:
Y
ello
w BRN:
Bro
w
n GRN:
Green ORG:
Or
ange
.
8.
When using the centr
al control system, Connect outdoor-outdoor tr
ansmission to F1
•
F2.
3D057078A
Pr
inted circuit board (Main)
Pr
inted circuit board (INV)
Push b
utton s
witch
(Mode
, set , retur
n, test, defrost)
Capacitor
Dip s
witch
Cr
ankcase heater
Fuse (T
, 6.3A, 250V)
Pilotlamp (Ser
vice monitor-or
ange)
[H2P] prepare
, test --------------Flic
ke
ring
malfunction detection---- Light up
Oper
ation Pilot Lamp
(Ser
vice monitor-g
reen)
Oper
ation Pilot Lamp
(Ser
vice monitor-g
reen)
Magnetic contactor
Magnetic rela
y (Y1S)
Magnetic rela
y (Y2S)
Magnetic rela
y (Y3S)
Magnetic rela
y (E1HC)
Magnetic rela
y
Reactor
Motor (Compressor)
Motor (F
an)
P
o
w
er supply
Resistor
Resistor
Ther
mistor (Air)
Ther
mistor (M1C Discharge)
Ther
mistor (Suction1)
Ther
mistor (Subcool1)
Ther
mistor (Suction2)
Ther
mistor (Coil)
Ther
mistor (Liquid1)
Ther
mistor (Liquid2)
Ther
mistor (P
o
w
er module)
Pressure sensor (High)
Pressure sensor (Lo
w)
Pressure s
w
itch (High)
P
o
w
er module
Diode module
T
e
rminal str
ip
T
e
rminal str
ip (Control)
(
C/H Selector)
Electronic e
xpansion v
a
lv
e (Main)
Electronic e
xpansion v
alv
e (Sub cool)
Solenoid v
alv
e (4
W
a
y v
alv
e)
Solenoid v
alv
e (Hot gas)
Solenoid v
alv
e (U/L Circuit)
Noise filter
Noise filter
Noise filter
Noise filter
Noise filter
(With surge absorber)
Noise filter
Selector s
w
itch (F
an/Cool • Heat)
Selector s
w
itch (Cool/Heat)
Connector
(Option adapter po
w
e
r supply)
Connector of option adapter
C/H Selector
THE POSITION OF
COMPRESSOR
TERMINAL
THE ENTRANCE
OF WIRE
HEA
T
COOL
NO
TE )8
NO
TE )4
AIR CONTR
O
L
PO
WER SUPPL
Y
3N~
380-415V
50Hz
EL, COMPO
, ASSY FR
ONT
ARR
O
W
A
SELECT
OR
COOL/HEA
T SELECT
OR
INDOOR
(F1) (F2)
OUTDOOR
(F1) (F2)
TO
IN/D UNIT
TO
OUT/D UNIT
FA
N
Содержание VRVIII-S
Страница 1: ...SiENBE34 703 Basic Training Manual R 410A Heat Pump 50Hz Service Manual...
Страница 11: ...Introduction SiENBE34 703 x...
Страница 16: ...SiENBE34 703 Specifications 5 Part 2 Specifications 1 Specifications 6 1 1 Outdoor Units 6 1 2 Indoor Units 8...
Страница 113: ...Field Setting SiENBE34 703 102 Test Operation...
Страница 207: ...Troubleshooting by Indication on the Unified ON OFF Control SiENBE34 703 196 Troubleshooting...
Страница 215: ...Wiring Diagrams SiENBE34 703 204 Appendix 2 3 Indoor Unit FXCQ20 25 32 63M8...
Страница 216: ...SiENBE34 703 Wiring Diagrams Appendix 205 FXCQ40 50 80 125M8V3...
Страница 217: ...Wiring Diagrams SiENBE34 703 206 Appendix FXFQ25 32 40 50 63 80 100 125P7VE...
Страница 218: ...SiENBE34 703 Wiring Diagrams Appendix 207 FXZQ20 25 32 40 50M8V1...
Страница 221: ...Wiring Diagrams SiENBE34 703 210 Appendix FXDQ20 25M8V3...
Страница 222: ...SiENBE34 703 Wiring Diagrams Appendix 211 FXSQ20 25 32 40 50 63 80 100 125M8V3...
Страница 232: ...SiENBE34 703 Option List Appendix 221...
Страница 235: ...Example of Connection SiENBE34 703 224 Appendix...
Страница 241: ...Method of Replacing the Inverter s Power Transistors Modules SiBE34 703 230 Appendix...
Страница 261: ...RXYSQ4 5 6 P7Y1B SiENBE34 703 250 Removal Procedure...