2
|
Components
Service manual
69
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
b
a
c
d
e
f
a
Grouding wire cover screw
b
Grounding wire screw
c
Heat exchanger thermistor
d
Indoor unit PCB
e
Switch box screw
f
Switch box
4
Disconnect the connectors of the indoor unit fan motor and the front wiring
from the indoor unit PCB
5
Remove the screw and remove the switch box from the indoor unit.
6
Click the indoor unit fan motor cover out of the indoor unit.
a
a
Indoor unit fan motor cover
7
Remove the rubber from the indoor unit.
8
Remove the indoor unit fan motor from the indoor unit.
9
To install the indoor unit fan motor, see
68].
To install the DC fan motor assembly
1
Install the indoor unit fan motor in its correct location on the fan.
2
Install the rubber in front of the fan motor.
3
Click the indoor unit fan motor cover on the indoor unit.
Содержание Stylish Series
Страница 166: ......
Страница 167: ......
Страница 168: ...ESIE18 03C 2020 02 Copyright 2018 Daikin Verantwortung f r Energie und Umwelt...