3
|
Components
Service manual
99
(A)(F)TXF20~71A + FTXF20~25B + (A)(F)TXF20~42C + (A)(F)TXF20~42D +
(A)(F)TXF20~42E + (A)RXF20~71A + RXF20~60B + (A)RXF20~42C +
(A)RXF20~42D + (A)RXF20~42E
Split Sensira R32
ESIE18-12G – 2023.01
e
d a b c
A
A
(A)RXF20~35D + (A)RXF20~42E units
a
U
b
V
c
W
d
DC+
e
DC–
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
VDC
Com
Ref
VDC
Com
Ref
U
DC+
0.501 V
DC+
U
O.L
V
DC+
0.501 V
DC+
V
O.L
W
DC+
0.501 V
DC+
W
O.L
DC–
U
0.501 V
U
DC–
O.L
DC–
V
0.501 V
V
DC–
O.L
DC–
W
0.501 V
W
DC–
O.L
Power module IPM2 for fan motor
1
Disconnect the fan motor connector from the main PCB.
2
Check the power module IPM2 in reference with the image and the table
below.