• Outdoor Unit • RZAG-MV1
2
• Split - Sky Air • RZAG-MV1
6
2
Specifications
Notes
(1) Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
(2) Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W]
Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
2-3 Capacity and Power input
FBA71A/
RZAG71MV1
FBA100A/
RZAG71MV1
FBA100A/
RZAG100MV1
FBA140A/
RZAG100MV1
FBA125A/
RZAG125MV1
FBA140A/
RZAG140MV1
Indoor unit
FBA71A2VEB
FBA100A2VEB
FBA140A2VE
B
FBA125A2VE
B
FBA140A2VE
B
Outdoor unit
RZAG71M7V1B
RZAG100M7V1B
RZAG125M7V
1B
RZAG140M7V
1B
Cooling capacity
Nom.
kW
6.80 (1)
9.50 (1)
12.1 (1)
13.4 (1)
Heating capacity
Nom.
kW
7.50 (2)
10.8 (2)
13.5 (2)
15.5 (2)
Space cooling
Energy efficiency class
A++
A+
A++
-
Capacity
Pdesign
kW
6.80
9.50
12.1
13.4
SEER
6.22
5.81
6.47
6.39
6.19
6.42
η
s,c
%
-
245
254
Annual energy consumption
kWh/a
382
410
514
520
1,173
1,252
A Condition (35°C -
27/19)
Pdc
kW
6.80
9.50
12.10
13.40
EERd
3.66
3.93
4.20
4.16
3.33
3.11
Power input
kW
1.86
1.73
2.26
2.28
3.64
4.30
B Condition (30°C -
27/19)
Pdc
kW
5.02
7.00
8.92
9.88
EERd
5.60
5.31
5.37
5.51
5.10
5.18
Power input
kW
0.90
0.94
1.30
1.27
1.75
1.91
C Condition (25°C -
27/19)
Pdc
kW
3.23
4.50
5.74
6.35
EERd
7.75
7.09
7.67
7.59
6.83
7.28
Power input
kW
0.42
0.46
0.59
0.84
0.87
D Condition (20°C -
27/19)
Pdc
kW
2.89
3.04
4.20
4.40
3.89
4.14
EERd
9.60
8.34
10.40
9.76
9.87
10.49
Power input
kW
0.30
0.36
0.40
0.45
0.39