• Split Sky Air • Outdoor Units
33
• Outdoor Units • R-410A • RXL-G2V1B
7
Wiring diagram
7 - 1
Wiring diagram
2
7
3D062389
RXL35G
R
: Protective earth
C74,C75,C94,C95
: Capacitor
DB1,DB2,DB3
: Diode bridge
FU1,FU2,FU3,FU4,FU5
: Fuse
PM1
: Power module
L
: Live
L1R
: Reactor
M1C
: Compressor motor
M1F
: Fan motor
MRC/W,MRM10,MRM20 : Magnetic relay
N
: Neutral
PCB1,2
: Printed circuit board
Q1L
: Overload protector
R1T-R3T
: Thermistor
AC1,1C2
U,V,W,X11A
E1,E2
HR1,HR2
S2-S102
: Connector
LEDA
: Pilot lamp
SW1
: Forced operation on/off
SW (SW1)
SW4
: Local setting SW (SW4)
g
Field wiring
Indoor
Outdoor
(outdoor)
(Condenser)
(discharge)
SA1
: Surge arrester
V2,V3,V5,V6,V11 : Varistor
X1M,X2M
: Terminal strip
Y1E
: Electronic expansion valve coil
Y1R
: Reversing solenoide valve coil
Z1C-Z5C
: Ferrite core
Q31
: IGBT
S1T
: Thermostat
E1H
: Heater
Sheet metal
: Terminal strip fixed plate
NOTE
1. Refer to purchasing specification
AS303002, unless otherwise
specified.
2. This drawing was drawn on CAD
system.
Drain pan
Heater
Sheet metal
In case of heat
pump type
Power
supply
To indoor
unit
Содержание RXL25G2V1B