• Outdoor Units • R-410A • RXL-G2V1B
• Split Sky Air • Outdoor Units
26
4
Capacity tables
4 - 1
Cooling capacity tables
2
4
FTXLRXL35G2V1B
Cooling
50Hz 220-240V
AFR
10.2
BF
0.18
Indoor
Outdoor temperature (°CDB)
EWB
EDB
20
25
30
32
35
40
(°C)
(°C)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
Heating
50Hz 220-240V
AFR
11.0
Indoor
Outdoor temperature (°CWB)
EDB
-10
-5
0
6
10
(°C)
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
3D062719
SYMBOLS
AFR:
Air flow rate
(m
3
/min)
BF:
Bypass factor
EWB:
Entering wet bulb temp.
(°C)
EDB:
Entering dry bulb temp.
(°C)
TC:
Total capacity
(kW)
SHC:
Sensible heating capacity
(kW)
PI:
Power input
(kW)
NOTES
1. Capacities are based on the following conditions:
Corresponding refrigerant piping length:
5 m
Level difference:
0 m
2.
shows nominal (rated) capacities and power input.
3. Ratings shown are net capacities which include a deduction for indoor fan
motor heat
4. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
5. About SHC which are not mentioned on the table, please calculate them
with around values in direct proportion.
6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above.