SYSTEM TESTING
Users are advised to test the system frequently. System must be tested at least
once every three
months
. If the system is not functioning accordingly, please contact the nearest dealer for
technical assistance. In order to test the alarm system, system must be on normal mode. There
are5
types
of tests: walk test, cms test, siren test, strobe light test and battery test.
5.2.1 WALK TEST
Command
Information
Initiate
Walk Test
Press
[COM]+[1]+[#]
Walk test allow on-site testing for each zone of the system
The keypad will beep twice upon confirmation
The
PWR
,
KEY
and
MEM
light will
FLASH
to indicate that
the system is currently under the
Walk Test.
Each time zone faulted, corresponding zone light will
fast
flash
and keypad will chime until system exit walk test.
To
exit
, press [
#]
key.
The keypad will beep twice upon confirmation. Back to
normal mode.
5.2.2 CMS TEST
Command
Information
Manual
test
reporting for
CMS
Press
[COM] +[2]+[#]
The keypad will beep twice upon confirmation. Panel will
generate message to CMS center.
5.2.3 SIREN TEST
Command
Information
Test siren
Press
[COM]+[3]+[#]
Once command has been acknowledged, the keypad and bell
will sound continuously for 3 seconds.
5.2.4 STROBE LIGHT TEST
Command
Information
Test strobe light
Press
[COM]+[4]+[#]
Once command has been acknowledged, the strobe light will
on continuously for 3 seconds.
5.2.5 BATTERY TEST
Command
Information
Test
back-up
battery
Press
[COM]+[5]+[#]
Battery test takes few seconds
The keypad will beep twice or reject toneas a result.
The indication of low battery can be seen from View System
Service Mode.