Electrical installation
Installer reference guide
49
4MWXM-A9
R32 Split series
4P708645-1 – 2022.09
MR30_A
S80
S70
D
C-
FU2
AL1
DP2
DP1
AL2
S60
S
S50
MR30_B
S20
S21
S22
S23
S93
S92
S90
W
V
U
S40
AC
DC
DC
c
e
d
f
b
a
l
k
j
i
g
h
DC(-)
FU2
a
AL1, AL2, DP1, DP2: solenoid valve lead wire connectors
b
S: terminal strip lead wire connector
c
S20~S22 (room A, B, C) + S23 (TO TANK): electronic expansion valve coil lead wire
connector,
d
MR30_A, MR30_B - suspend lead wire connectors
e
S40: thermal overload relay lead wire and high pressure switch connector
f
Multimeter (DC voltage range)
g
S90, S92, S93: thermistor lead wire connector
h
S50: suspend lead wire connector
i
S60: pressure sensor connector
j
S70: fan motor lead wire connector
k
S80: 4-way valve lead wire connector
l
W, V, U: Compressor lead wire connector
WARNING
▪
All wiring MUST be performed by an authorised electrician and MUST comply
with the applicable national wiring regulation.
▪
Make electrical connections to the fixed wiring.
▪
All components procured on-site and all electrical construction MUST comply
with the applicable legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
INFORMATION
Also read the precautions and requirements in the
7].
INFORMATION
Содержание Multi+ R32 Split Series
Страница 1: ...Installer reference guide R32 Split series 4MWXM52A2V1B9...
Страница 31: ...6 Unit installation Installer reference guide 31 4MWXM A9 R32 Split series 4P708645 1 2022 09...
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ...4P708645 1 2022 09 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...