SiBE81-909
Removal Procedure
Humidifying Air Purifier
91
8.9
Removal of Proximity Switch
Warning
Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Removal of the
proximity switch
1
Remove the screw and
remove the drip-proof
plate.
2
Remove the screw and
remove the proximity
sensor.
3
Disconnect the
connector of the limit
switch [S115].
(R9842)
Proximity sensor
Drip-proof
plate
(R9843)
In case of OFF
In case of ON
Proximity
sensor
When assembling
insert the harness
into the slit.
(R9844)
[S115]
Limit
switch
Holding plate
Содержание MCK75JVM-K
Страница 1: ...SiBE81 909 Humidifying Air Purifier...