SiBE81-909
Operation Manual
Humidifying Air Purifier
43
34
UNIT2
Notes
(4) Streamer unit
Open the front panel and pull out the
streamer unit.
• Do not remove the screws from the ionizing frame or streamer unit.
This may lead to damage.
• Clean UNIT1 and UNIT2 somewhere that can be wet such as in a shower
room or kitchen sink.
• For stubborn dirt, soak UNIT1 and UNIT2 in lukewarm or plain water in
which neutral liquid detergent (i.e., kitchen cleaner, etc.) has been
dissolved.
• Use the amount of neutral liquid detergent indicated in the cleaner’s
instructions.
• Do not use powdered, alkaline or acidic cleaners, and do not rub with hard
bristle brushes, etc.
Abusive handling may lead to deformation and damage.
• Do not touch the needles inside
(streamer unit).
Deodorizing capacity diminishes if the needles are deformed.
• If cleaner remains on UNITS 1 or 2, the “UNIT1” and “UNIT2” lamps do not
go out after cleaning, therefore rinse off the cleaner well.
• Do not leave any lint from cleaning cloths behind. Lint may lead to malfunction.
• Plastic parts may deform or discolor if exposed to direct sunlight.
• If water remains on UNITS 1 or 2, even in small quantities, the “UNIT1” and
“UNIT2” lamps do not go out after cleaning, therefore dry thoroughly in a
shade.
Reattach the streamer unit as before.
(2) Ionized wire (8 locations)
• Remove dirt from ionized wires and
surrounding plastic parts with a soft piece
of cloth.
(4) Streamer unit
• Remove dirt from plastic parts (
) in internal
areas with a cotton swab or soft piece of
cloth.
• Do not remove the screws.
CAUTION
There are ionized wires to the rear of the opposing pole plates.
Be careful not to snap these wires when removing and
attaching the units.
• If the unit is run with broken ionized wires, the “UNIT1” lamp
lights. While the lamp is lit, dust collecting capacity is low.
• If the ionized wires are accidentally snapped, they need
replacing, therefore contact the service shop. (Do not
replace the wires yourself.)
UNIT1
UNIT2
(Plasma ionizer)
(Streamer unit)
(1) Ionizing frame
(2) Ionized wire (Rear)
(3) Opposing
pole plates
(4) Streamer unit
UNIT2
Wipe
Wear rubber
gloves.
(For details, see (4)
in the below figure.)
Wear rubber
gloves.
Clean the ionized wires
without dislodging them
from the V-groove.
*Wipe ionized wires gently.
Pulling on them forcefully may
cause them to snap.
Wear rubber
gloves.
Do not touch
the needles.
*Do not touch the needles (2 locations).
Deodorizing capacity diminishes if the
needles are deformed.
Cotton
swab
: Plastic parts