![Daikin LRLEQ10AY1(E) Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/daikin/lrleq10ay1-e/lrleq10ay1-e_service-manual_502370081.webp)
Troubleshooting
SiENBE28-901
80
Air Cooled Refrigeration Condensing Unit
6.5
Troubleshooting by RAM Monitor
Using the RAM monitor makes it possible to check the following operating data. Use this
monitor for troubleshooting.
[Main]
[Mode]
SP_No.
SP number
Ver.
Version of software (Used for updating the software for PCB)
Hp_code
The comparison between HP_code and the model on the RAM Monitor
screen is as follows.
1:5AY1, 2:6AY1, 3:8AY1, 4:10AY1, 5:12AY1, 6:15AY1, 7:20AY1
Operation_SW
OPERATION switch bits (OFF/ON:0/1)
unit_driving
No need for checking because it is not used.
Mode
Present mode of operation
Next_mode
The following mode of operation
Before_mode
The previous mode of operation
Mode_complete
Driving mode completion bits (OFF/ON:0/1)
Start_complete
Start driving completion bits (OFF/ON:0/1)