SiENBE04-925_A
Main Functions
Function and Control
21
Drawing of
Inverter
The following drawing shows a schematic view of the inverter principle:
Inverter Features
The inverter provides the following features:
The regulating capacity can be changed according to the changes in the outdoor
temperature and cooling / heating load.
Quick heating and quick cooling
The compressor rotational speed is increased when starting the heating (or cooling). This
enables to reach the set temperature quickly.
Even during extreme cold weather, the high capacity is achieved. It is maintained even when
the outdoor temperature is 2°C.
Comfortable air conditioning
A fine adjustment is integrated to keep the room temperature constant.
Energy saving heating and cooling
Once the set temperature is reached, the energy saving operation enables to maintain the
room temperature at low power.
Frequency Limits
The following functions regulate the minimum and maximum frequency:
Forced Cooling
Operation
Refer to “Forced operation mode” on page
48
for detail.
Refrigerant circulation rate (high)
high f
low f
freq=variable
Refrigerant circulation rate (low)
high speed
low speed
(R2812)
Amount of heat
exchanged air (large)
freq=
constant
50 Hz
60 Hz
capacity=
variable
Amount of heat
exchanged air (small)
AC
po
w
e
r
DC po
w
er
Amount of heat
exchanged air (large)
Amount of heat
exchanged air (small)
Frequency
Functions
Low
Four way valve operation compensation. Refer to page 38.
High
Compressor protection function. Refer to page 38.
Discharge pipe temperature control. Refer to page 39.
Input current control. Refer to page 40.
Freeze-up protection control. Refer to page 41.
Heating peak-cut control. Refer to page 41.
Defrost control. Refer to page 43.
SIENBE04-925_A_FRONT.pdf 35
24/02/2011 13:53:51
Содержание Inverter FTXL20G2V1B
Страница 8: ...SiENBE04 925_A vi Table of Contents...
Страница 14: ...Introduction SiENBE04 925_A xii...
Страница 15: ...SiENBE04 925_A List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 17: ...SiENBE04 925_A Specifications 3 Part 2 Specifications 1 Specifications 4...
Страница 20: ...Specifications SiENBE04 925_A 6 Specifications...
Страница 186: ...SiENBE04 925_A Outdoor Unit RXL20G2V1B Removal Procedure 171 4 Feature of the thermistors Step Procedure Points R9356...