CAUTION
2
• Do not allow children to climb on the outdoor unit and avoid
placing objects on the unit.
Injury may result if the unit becomes loose and falls.
• Make sure to provide for adequate measures in order to
prevent that the outdoor unit be used as a shelter by small
animals.
Small animals making contact with electrical parts can cause
malfunctions, smoke or fire. Please instruct the customer to
keep the area around the unit clean.
• Install in a machine room that is free of moisture. The unit is
designed for indoor use.
• Disposal requirements
Dismantling of the unit, treatment of the refrigerant, of oil
and of other parts must be done in accordance with relevant
local and national legislation.
• Install drain piping according to this installation manual to
ensure good drainage, and insulate the piping to prevent
condensation.
Improper drain piping may cause water leakage, make the
furniture get wet.
• Install the air conditioner, power supply wiring, remote
controller wiring and transmission wiring at least 1 meter
away from televisions or radios to prevent image interference
or noise.
(Depending on the radio waves, a distance of 1 meter may
not be sufficient to eliminate the noise.)
• Install the indoor unit as far as possible from fluorescent
lamps.
If a wireless remote controller kit is installed, the transmission
distance may be shorter in a room where an electronic lighting
type (inverter or rapid start type) fluorescent lamp is installed.
• Do not install the air conditioner in places such as the
following:
1. Where there is mist of oil, oil spray or vapour for example
a kitchen.
Resin parts may deteriorate, and cause them to fall out
or water to leak.
2. Where corrosive gas, such as sulfurous acid gas, is
produced.
Corrosion of copper pipings or brazed parts may cause
the refrigerant to leak.
3. Where there is machinery which emits electromagnetic
waves.
Electromagnetic waves may disturb the control system,
and cause malfunction of the equipment.
4. Where flammable gases may leak, where carbon fibre
or ignitable dust is suspended in the air or where volatile
flammables, such as thinner or gasoline, are handled.
If the gas should leak and remained around the air
conditioner, it may cause ignition.
• Pay attention to product transportation.
Carry by hold the handle position that display on packing
material.
In case of hold PP hand, PP band will get loose, it will be
dangerous.
When unpacking the indoor unit or moving the unit after
unpacked, hold the hangers (4 places) and do not apply
force to other parts (particularly refrigerant piping, drain
piping and resin parts).
• Make sure to check in advance that the refrigerant to be
used for installation work is R410A.
(The air conditioner will not properly operate if a wrong
refrigerant is used.)
• For installation of the outdoor unit, refer to the installation
manual attached to the outdoor unit.
• Do not throw away the accessories until the installation work
is completed.
• After the indoor unit is carried into the room, to avoid the
indoor unit from getting damaged, take measures to protect
the indoor unit with packing materials.
(1) Determine the route to carry the unit into the room.
(2) Do not unpack the unit until it is carried to the installation
location.
Where unpacking is unavoidable, use a sling of soft
material or protective plates together with a rope when
lifting, to avoid damage or scratches to the indoor unit.
• Have the customer actually operate the air conditioner while
looking at the operation manual.
Instruct the customer how to operate the air conditioner
(particularly cleaning of the air filters, operation pro cedures,
and temperature adjustment).
• For selection of installation location, use the installation
pattern paper as reference.
• Do not use the air conditioner where in the salty atmosphere
such as coastal areas, vehicles, vessels or the voltage
fluctuation is frequent such as factories.
• Take off static electricity from the body when carrying out
wiring and the control box lid is removed.
The electric parts may be damaged.
2. BEFORE INSTALLATION
• Since design pressure is 4.0 MPa or 40 bar (for R407C units:
3.3 MPa or 33 bar), the thickness of pipes must be greater
than previously. Since R410A is a mixed refrigerant, the
required additional refrigerant must be charged in its liquid
state.
(If the system is charged with refrigerant in its gaseous state,
due to composition change, the system will not function
normally). The indoor unit is designed for R410A use.
See the catalogue for indoor unit models that can be
connected. (Normal operation is not possible when
connecting units that are originally designed for other
refrigerants.)
SPECIAL NOTICE PRODUCT
Clean and dry
Strict measures must be taken to keep impurities
(including SUNISO oil and other mineral oils as well as
moisture) out of the system.
Tightly sealed
R410A contains no chlorine, does not destroy the ozone
layer and so does not reduce the earth's protection against
harmful ultraviolet radiation. R410A will contribute only
slightly to the greenhouse effect if released into the
atmosphere.
• The refrigerant R410A requires that strict precautions be
observed for keeping the system clean, dry and tightly
sealed.
Содержание FXFSQ-AVM
Страница 1: ...FXFSQ AVM EDFMT391769A 201802 Engineering Data 50 60 Hz...
Страница 2: ......
Страница 11: ...FXFSQ AVM EDFMT391769A 9 FXFSQ63AVM FXFSQ80AVM 3D112982A Unit mm...
Страница 12: ...FXFSQ AVM EDFMT391769A 10 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112977A Unit mm...
Страница 13: ...FXFSQ AVM EDFMT391769A 11 3 2 Standard Panel FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM FXFSQ50AVM 3D112987A Unit mm...
Страница 14: ...FXFSQ AVM EDFMT391769A 12 FXFSQ63AVM FXFSQ80AVM 3D112983A Unit mm...
Страница 15: ...FXFSQ AVM EDFMT391769A 13 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112979A Unit mm...
Страница 16: ...FXFSQ AVM EDFMT391769A 14 3 3 Designer Panel FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM FXFSQ50AVM 3D112988A Unit mm...
Страница 17: ...FXFSQ AVM EDFMT391769A 15 FXFSQ63AVM FXFSQ80AVM 3D112985A Unit mm...
Страница 18: ...FXFSQ AVM EDFMT391769A 16 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112980A Unit mm...
Страница 19: ...FXFSQ AVM EDFMT391769A 17 3 4 Auto Grille Panel FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM FXFSQ50AVM 3D112991A Unit mm...
Страница 20: ...FXFSQ AVM EDFMT391769A 18 FXFSQ63AVM FXFSQ80AVM 3D112986A Unit mm...
Страница 21: ...FXFSQ AVM EDFMT391769A 19 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112981A Unit mm...
Страница 28: ...FXFSQ AVM EDFMT391769A 26 9 Sound Levels FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM 4D112880A 4D112874A...
Страница 29: ...FXFSQ AVM EDFMT391769A 27 FXFSQ50AVM FXFSQ63AVM 4D112898A 4D112879B...
Страница 30: ...FXFSQ AVM EDFMT391769A 28 FXFSQ80AVM FXFSQ100AVM 4D112878B 4D509733A...
Страница 31: ...FXFSQ AVM EDFMT391769A 29 FXFSQ125AVM FXFSQ140AVM 4D509732A 4D509731A...
Страница 55: ......