Electrical installation

Installer and user reference guide

71

FXAA15~63AUV1B
VRV system air conditioner
4P622295-1A – 2020.10

a

a

Electrical wiring

Complete system example

1 user interface controls 1 indoor unit.

L

N

L

N

L

N

IN/D OUT/D

F

1

F

2

F

1

F

2

Control box

P

1

P

2

P

1

P

2

P

1

P

2

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

F

1

F

2

T

1

T

2

N L

a

d

c

b

L

N

N L

N L

N L

a

Outdoor unit

b

Indoor unit

c

User interface

d

Most downstream indoor unit

NOTICE

Group control connection is NOT allowed.

CAUTION

Each indoor unit has to be connected to a separate user interface. Only a safety
system  compatible  remote  controller  can  be  used  as  the  user  interface.  See
technical data sheet for remote controller compatibility (e.g. BRC1H52/82*).

The user interface has to be put in the same room as the indoor unit. For details,
please refer to the installation and operation manual of the user interface.

Содержание FXAA15AUV1B

Страница 1: ...Installer and user reference guide VRV system air conditioner FXAA15AUV1B FXAA20AUV1B FXAA25AUV1B FXAA32AUV1B FXAA40AUV1B FXAA50AUV1B FXAA63AUV1B...

Страница 2: ...system 30 9 Energy saving and optimum operation 31 10 Maintenance and service 32 10 1 Precautions for maintenance and service 32 10 2 Cleaning the unit 33 10 2 1 To clean the air outlet and exterior...

Страница 3: ...56 16 3 5 To pass the pipes through the wall hole 57 16 3 6 To provide drainage 58 17 Piping installation 61 17 1 Preparing refrigerant piping 61 17 1 1 Refrigerant piping requirements 61 17 1 2 Refri...

Страница 4: ...contents Installer and user reference guide 4 FXAA15 63AUV1B VRV system air conditioner 4P622295 1A 2020 10 25 Technical data 82 25 1 Wiring diagram 82 25 1 1 Unified wiring diagram legend 82 26 Glos...

Страница 5: ...of General safety precautions Safety instructions that you must read before installing Format Paper in the box of the indoor unit Indoor unit installation and operation manual Installation and operati...

Страница 6: ...aning of warnings and symbols DANGER Indicates a situation that results in death or serious injury DANGER RISK OF ELECTROCUTION Indicates a situation that could result in electrocution DANGER RISK OF...

Страница 7: ...act your dealer DANGER RISK OF BURNING SCALDING Do NOT touch the refrigerant piping water piping or internal parts during and immediately after operation It could be too hot or too cold Give it time t...

Страница 8: ...me and address of fire department police and hospital Name address and day and night telephone numbers for obtaining service In Europe EN378 provides the necessary guidance for this logbook 2 2 2 Inst...

Страница 9: ...tic pump down function with which you can collect all refrigerant from the system into the outdoor unit Possible consequence Self combustion and explosion of the compressor because of air going into t...

Страница 10: ...cedure is done or when pausing close the valve of the refrigerant tank immediately If the valve is NOT closed immediately remaining pressure might charge additional refrigerant Possible consequence In...

Страница 11: ...the earth leakage protector CAUTION When connecting the power supply connect the earth cable first before making the current carrying connections When disconnecting the power supply disconnect the cu...

Страница 12: ...x is connected securely Make sure all covers are closed before starting up the unit NOTICE Only applicable if the power supply is three phase and the compressor has an ON OFF starting method If there...

Страница 13: ...cured area protected from easy access This unit both indoor and outdoor is suitable for installation in a commercial and light industrial environment CAUTION For walls containing a metal frame or a me...

Страница 14: ...uit breakers Secure the electrical wiring with cable ties so that the cables do NOT come in contact with sharp edges or piping particularly on the high pressure side Do NOT use taped wires stranded co...

Страница 15: ...ion sources example open flames an operating gas appliance or an operating electric heater in case the floor area is less than the minimum floor area A m no auxiliary devices which may be a potential...

Страница 16: ...irements CAUTION The total refrigerant charge in the system cannot exceed the requirements for minimum floor area of the smallest room that is served For minimum floor area requirements for indoor uni...

Страница 17: ...For the user Installer and user reference guide 17 FXAA15 63AUV1B VRV system air conditioner 4P622295 1A 2020 10 For the user...

Страница 18: ...tal capabilities or lack of experience and knowledge can only use this appliance if they have been given supervision or instruction concerning the use of the appliance by a person responsible for thei...

Страница 19: ...attery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries must be treated at a specialized treatment facility for reuse By ensuring waste...

Страница 20: ...r CAUTION It is unhealthy to expose your body to the air flow for a long time CAUTION To avoid oxygen deficiency ventilate the room sufficiently if equipment with burner is used together with the syst...

Страница 21: ...inspect the unit while the fan is running Be sure to turn off the main switch before executing any maintenance task CAUTION Do NOT insert fingers rods or other objects into the air inlet or outlet Wh...

Страница 22: ...rces example open flames an operating gas appliance or an operating electric heater WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defro...

Страница 23: ...ce the sensor after every detection or at the end of the lifetime Authorized person only MUST replace the sensor Troubleshooting see 11 Troubleshooting 438 WARNING Stop operation and shut off the powe...

Страница 24: ...rected before resuming operation NOTICE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for cooling precision instruments food plants animals o...

Страница 25: ...ooling capacity sensible Prated c A kW Cooling capacity latent Prated c B kW Heating capacity Prated h C kW Total electric power input Pelec D kW Sound power level per speed setting if applicable LWA...

Страница 26: ...chemical dust cloth etc The panel may get discoloured or the coating peeled off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it...

Страница 27: ...used together with the system CAUTION Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensit...

Страница 28: ...back A function that keeps the room temperature in a specific range when the system is turned off by the user the schedule function or the OFF timer 8 2 1 Basic operation modes The indoor unit can ope...

Страница 29: ...on and the following icon will appear on the home screen 8 2 3 Airflow direction When Adjust the airflow direction as desired What The system directs the airflow differently depending on the user sele...

Страница 30: ...djust the louvers vertical blades 1 Adjust horizontal blades using the user interface so you can easily access the knobs on the vertical blades 2 Hold knobs and move them down slightly 3 Adjust left o...

Страница 31: ...Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Make sure the area is well ventilated Do NOT block any ventilation openings Ventilate often Extended u...

Страница 32: ...he unit by yourself Ask a qualified service person to perform this work However as end user you may clean the air outlet exterior front panel and air filter WARNING NEVER replace a fuse with a fuse of...

Страница 33: ...rmly when washing the blade with water Possible consequence The surface sealing peels off Clean with a soft cloth If it is difficult to remove stains use water or neutral detergent 10 2 2 To clean the...

Страница 34: ...le consequence Discoloration and deformation When to clean the air filter Rule of thumb Clean every 6 months If the air in the room is extremely contaminated increase the cleaning frequency Depending...

Страница 35: ...stop period E g at the end of the season Let the indoor units run in fan only operation for about half a day in order to dry the interior of the units Clean air filters and casings of indoor units see...

Страница 36: ...ARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may re...

Страница 37: ...indicator is blinking 3 Sensor checks if refrigerant leakage or misdetection occurred If refrigerant leakage is NOT detected Result system returns to normal operation after approximately 2 minutes If...

Страница 38: ...perly Turn OFF all main power supply switches to the unit If water leaks from the unit Stop operation The operation switch does NOT function properly Turn OFF the power supply If the user interface di...

Страница 39: ...malfunctions The following symptoms are NOT system malfunctions 11 1 1 Symptom The system does not operate The air conditioner does not start immediately after the ON OFF button on the user interface...

Страница 40: ...her than the air conditioner The noise prevents communication between the units causing them to stop Operation automatically restarts when the noise ceases 11 1 7 Symptom Noise of air conditioners Ind...

Страница 41: ...taller and user reference guide 41 FXAA15 63AUV1B VRV system air conditioner 4P622295 1A 2020 10 12 Relocation Contact your dealer for removing and reinstalling the total unit Moving units requires te...

Страница 42: ...r 4P622295 1A 2020 10 13 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Страница 43: ...For the installer Installer and user reference guide 43 FXAA15 63AUV1B VRV system air conditioner 4P622295 1A 2020 10 For the installer...

Страница 44: ...nformation about Unpacking and handling the unit Removing the accessories from the unit Keep the following in mind At delivery the unit MUST be checked for damage Any damage MUST be reported immediate...

Страница 45: ...1A 2020 10 1 2 2 14 2 2 To remove the accessories from the indoor unit 8 9 2 1 1 4 1 c b a d 1 e f a Installation and operation manual b General safety precautions c Screw pack M4 25L 8 for FXAA15 32...

Страница 46: ...ining units and options 47 15 4 1 Possible options for the indoor unit 47 15 1 Identification NOTICE When installing or servicing several units at the same time make sure NOT to switch the service pan...

Страница 47: ...stem compatible remote controller can be used See technical data sheet for remote controller compatibility e g BRC1H52 82 Note The user interface will generate a visible and audible warning sign in ca...

Страница 48: ...same room as the indoor unit For details please refer to the installation and operation manual of the user interface Optional output PCB to provide output for external device The PCB will trigger in...

Страница 49: ...e Do NOT install the unit in places often used as work place In case of construction works e g grinding works where a lot of dust is created the unit MUST be covered Choose an installation location wi...

Страница 50: ...In places with weak reception keep distances of 3 m or more to avoid electromagnetic disturbance of other equipment and use conduit tubes for power and transmission lines Take care that in the event...

Страница 51: ...he installation and operation manual of the outdoor unit 16 2 Opening and closing the unit 16 2 1 To remove the front panel 1 Open the front panel Hold the front panel by the panel tabs on both sides...

Страница 52: ...r hooks marked with a symbol with 3 circles in the direction of the arrows Remove cardboard between the filter and the heat exchanger a b a Hook b Cardboard 4 Making sure not to catch the horizontal f...

Страница 53: ...er 16 3 1 To install the mounting plate 53 16 3 2 To drill a wall hole 55 16 3 3 To remove the pipe port cover 56 16 3 4 To hook the unit on the mounting plate 56 16 3 5 To pass the pipes through the...

Страница 54: ...arily 5 Level the mounting plate use tabs on the mounting plate 6 Mark the centers of the drilling points on the wall using a tape measure Position the end of tape measure at symbol 7 Finish the insta...

Страница 55: ...at symbol g Gas pipe end h Liquid pipe end i Temporary fixing hole 16 3 2 To drill a wall hole CAUTION For walls containing a metal frame or a metal board use a wall embedded pipe and wall cover in t...

Страница 56: ...1 Remove the front grille 16 2 3 To remove the front grille 452 2 Cut off the pipe port cover from inside the front grille using a coping saw 3 Remove any burrs along the cut section using a half rou...

Страница 57: ...ng 17 Piping installation 461 and the electrical wiring 18 Electrical installation 467 2 Shape the refrigerant pipes along the pipe path marking on the mounting plate 3 Fix the electrical wiring and t...

Страница 58: ...To provide drainage Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the indoor unit Checking for water leaks General guidelines P...

Страница 59: ...f the drain pipe 50 mm Condensation Take measures against condensation Insulate the complete drain piping in the building To connect the piping on right side right back or right bottom INFORMATION The...

Страница 60: ...the drain hose on the left side and do not forget to tighten it with the fixing screw otherwise water leakage may occur 4 Attach the drain hose to the refrigerant piping bottom side using adhesive vin...

Страница 61: ...ments INFORMATION Also read the precautions and requirements in the 2 General safety precautions 46 CAUTION Piping MUST be installed according to instructions given in 17 Piping installation 461 Only...

Страница 62: ...120 C Insulation thickness 6 4 mm 1 4 8 10 mm 10 mm 9 5 mm 3 8 12 15 mm 13 mm 12 7 mm 1 2 14 16 mm 13 mm i i t p p If the temperature is higher than 30 C and the humidity is higher than RH 80 the thic...

Страница 63: ...adding refrigerant Only use installation tools e g manifold gauge set that are exclusively used for R32 installations to withstand the pressure and to prevent foreign materials e g mineral oils and mo...

Страница 64: ...0 4 0 8 2 45 90 2 A 9 5 33 39 12 8 13 2 12 7 50 60 16 2 16 6 17 2 4 Pipe bending guidelines Use a pipe bender for bending All pipe bends should be as gentle as possible bending radius should be 30 40...

Страница 65: ...onents containing refrigerant unless the components are constructed of materials that are inherently resistant to corrosion or are suitably protected against corrosion WARNING MILDLY FLAMMABLE MATERIA...

Страница 66: ...installation Installer and user reference guide 66 FXAA15 63AUV1B VRV system air conditioner 4P622295 1A 2020 10 NOTICE Make sure to insulate all refrigerant piping Any exposed piping might cause con...

Страница 67: ...ower supply system complies with the electrical specifications of the units 2 Connecting the electrical wiring to the outdoor unit 3 Connecting the electrical wiring to the indoor unit 4 Connecting th...

Страница 68: ...use this unit is equipped with an inverter A phase advancing capacitor will reduce performance and may cause accidents WARNING Use an all pole disconnection type breaker with at least 3 mm between the...

Страница 69: ...een the wire retainer and the terminal must be longer than the other wires 18 1 3 Specifications of standard wiring components Component Class 15 20 25 40 50 63 Power supply cable MCA a 0 3 A 0 4 A 0...

Страница 70: ...pply wiring may cross but may NOT run parallel 1 Remove the service cover see 16 2 5 To open the service cover 452 2 User interface cable Connect the cable to the terminal block symbols P1 P2 3 Transm...

Страница 71: ...T1 T2 N L a d c b L N N L N L N L a Outdoor unit b Indoor unit c User interface d Most downstream indoor unit NOTICE Group control connection is NOT allowed CAUTION Each indoor unit has to be connect...

Страница 72: ...nting plate Make sure that the wires do NOT get squeezed or caught anywhere 3 Press the bottom edge of the indoor unit with both hands until it is firmly caught by the mounting plate hooks 4 Secure th...

Страница 73: ...of 50 hours before reaching smooth operation and stable power consumption NOTICE Before starting up the system the unit MUST be energised for at least 6 hours to avoid compressor breakdown during star...

Страница 74: ...tion devices are installed according to this document and have NOT been bypassed The power supply voltage matches the voltage on the identification label of the unit There are NO loose connections or...

Страница 75: ...nal accessory Following setting are only applicable when using the BRC1H52 user interface When using any other user interface see the installation manual or service manual of the user interface Settin...

Страница 76: ...1 M SW 200 h light 10 20 0 01 100 h heavy 02 Notification ON 3 01 Notification OFF 02 Setting Thermostat sensor selection This setting must correspond with how if the remote controller thermostat sen...

Страница 77: ...int in automatic mode availability depends on the system type Differential is cooling setpoint minus heating setpoint If you want to set the temperature difference value to Then 1 M SW 0 C 12 22 4 01...

Страница 78: ...rly please make sure the following is clear for the user Make sure that the user has the printed documentation and ask him her to keep it for future reference Inform the user that he can find the comp...

Страница 79: ...de Description The R32 sensor has detected a refrigerant leak Safety system error leak detection R32 sensor malfunction R32 sensor end of lifetime 6 months before the R32 sensor end of lifetime Malfun...

Страница 80: ...23 Troubleshooting Installer and user reference guide 80 FXAA15 63AUV1B VRV system air conditioner 4P622295 1A 2020 10 Code Description Room temperature thermistor in remote controller abnormality...

Страница 81: ...r 4P622295 1A 2020 10 24 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Страница 82: ...he unit Part numbering is by Arabic numbers in ascending order for each part and is represented in the overview below by in the part code Symbol Meaning Symbol Meaning Circuit breaker Protective earth...

Страница 83: ...e HAP Light emitting diode service monitor green HIGH VOLTAGE High voltage IES Intelligent eye sensor IPM Intelligent power module K R KCR KFR KHuR K M Magnetic relay L Live L Coil L R Reactor M Stepp...

Страница 84: ...ensor low S PH HPS Pressure switch high S PL Pressure switch low S T Thermostat S RH Humidity sensor S W SW Operation switch SA F1S Surge arrester SR WLU Signal receiver SS Selector switch SHEET METAL...

Страница 85: ...or application explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenance instruct...

Страница 86: ......

Страница 87: ......

Страница 88: ...4P622295 1A 2020 10 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: