39
English
3P326999-1
FUQ71 • 100 • 125CVEB
SELECTOR SWITCH
(MAIN/SUB)
SELECTOR SWITCH
(WIRELESS ADDRESS SET)
SS1
SS2
PRINTED CIRCUIT BOARD
PRINTED CIRCUIT BOARD
CAPACITOR (M1F)
DIP SWITCH ON PCB
FLASHING LAMP
(SERVICE MONITOR GREEN)
MAGNETIC RELAY
MOTOR (INDOOR FAN)
MOTOR (DRAIN PUMP)
MOTOR (SWING BLADE)
THERMISTOR (AIR)
THERMISTOR (COIL)
FLOAT SWITCH
DIODE BRIDGE
TERMINAL BLOCK
TERMINAL BLOCK
NOISE FILTER
FERRITE CORE
FERRITE CORE
POWER SUPPLY CIRCUIT
SIGNAL RECEIVER CIRCUIT
SIGNAL TRANSMISSION
CIRCUIT
PRINTED CIRCUIT BOARD
PRINTED CIRCUIT BOARD
PUSH BUTTON (ON/OFF)
PILOT LAMP (ON-RED)
PILOT LAMP
(TIMER-GREEN)
PILOT LAMP
(FILTER SIGN-RED)
PILOT LAMP
(DEFROST-ORANGE)
A1P
A2P
C105
DS1
HAP
K2R
M1F
M1P
M1S·M2S
M3S·M4S
R1T
R2T·R3T
S1L
V1R
X1M
X2M
Z1F
Z1C
Z2C
PS
RC
TC
A3P
A4P
BS1
H1P
H2P
H3P
H4P
WIRED REMOTE CONTROLLER
THERMISTOR (AIR)
R1T
CONNECTOR
(WIRELESS REMOTE
CONTROLLER)
CONNECTOR
(POWER SUPPLY FOR
ADAPTOR)
X24A
X35A
WIRING DIAGRAM
WIRELESS REMOTE CONTROLLER
(RECEIVER / DISPLAY UNIT)
INDOOR UNIT
2. IN CASE OF SIMULTANEOUS OPERATION INDOOR UNIT SYSTEM.
SEE THE INDOOR UNIT WIRING ONLY.
3.
FOR THE DETAIL, SEE WIRING DIAGRAM ATTACHED TO OUTDOOR UNIT.
4.
IN CASE USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH THE ATTACHED
INSTALLATION MANUAL.
5.
IN CASE OF SIMULTANEOUS OPERATION SYSTEM, CONNECTION QUANTITY OF THE INDOOR UNITS VARIES ACCORDING TO
THE CONNECTION OUTDOOR UNIT, CONFIRM TECHNICAL GUIDE AND CATALOG, ETC. BEFORE CONNECTING.
6.
IN CASE OF MAIN/SUB CHANGEOVER.
SEE THE INSTALLATION MANUAL ATTACHED TO REMOTE CONTROLLER.
7.
SYMBOLS SHOW AS FOLLOWS: BLK:BLACK RED:RED BLU:BLUE WHT:WHITE YLW:YELLOW GRN:GREEN ORG:ORANGE
BRN:BROWN.
8.
SHOWS ONLY IN CASE OF PROTECTED PIPING. USE H07RN-F IN CASE OF NO PROTECTION.
: TERMINAL BLOCK : CONNECTOR
: FIELD WIRING
1.
NOTES
,
CONNECTOR FOR
OPTIONAL PARTS
5
4
33
1
2
6
7
8
9
10
11
12
Fig. 51
01_EN_3P177351-6P.fm Page 39 Sunday, September 30, 2012 1:52 PM