Instructions
SiBE01-829
48
Operation Manual
2.12
Troubleshooting
21
TROUBLE SHOOTING
Trouble Shooting
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
These cases are not troubles.
Case
Explanation
Operation does not start soon.
• When ON/OFF button was
pressed soon after operation
was stopped.
• When the mode was reselected.
• This is to protect the air conditioner.
You should wait for about 3 minutes.
Hot air does not flow out soon
after the start of heating
operation.
• The air conditioner is warming up. You should wait for 1 to 4
minutes.
(The system is designed to start discharging air only after it
has reached a certain temperature.)
The heating operation stops
suddenly and a flowing sound
is heard.
• The system is taking away the frost on the outdoor unit.
You should wait for about 3 to 10 minutes.
The outdoor unit emits water or
steam.
HEAT mode
• The frost on the outdoor unit melts into water or steam
when the air conditioner is in defrost operation.
COOL or DRY mode
• Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.
Mist comes out of the indoor
unit.
This happens when the air in the room is cooled into mist by
the cold airflow during cooling operation.
The indoor unit gives out odour.
This happens when smells of the room, furniture, or cigarettes
are absorbed into the unit and di scharged with the airflow.
(If this happens, we recommend you to have the indoor unit
washed by a technician. Consult the service shop where you
bought the air conditioner.)
The outdoor fan rotates while
the air conditioner is not in
operation.
After operation is stopped:
• The outdoor fan continues rotating for another 60 seconds
for system protection.
While the air conditioner is not in operation:
• When the outdoor temperature is very high, the out door
fan starts rotating for system protection.
The operation stopped
suddenly.
(OPERATION lamp is on.)
For system protection, the air conditioner may stop operating
on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.
No remote controller signals are
displayed.
The remote controller
sensitivity is low.
The display is low in contrast or
blacked out.
The display runs out of control.
• The batteries are dying and the remote controller is
malfunctioning. Replace all the batteries with new size AAA
alkaline batteries. For details, refer to “To set the batteries” of
this manual. (page 7.)
* If the reset button is provided, press the reset button after the
batteries are replaced.
Содержание FTYN25GXV1B
Страница 1: ...SiBE01 829 Applied Models Non Inverter Pair Heat Pump SPLIT Pair Wall Mounted Type G Series...
Страница 11: ...Introduction SiBE01 829 x...
Страница 12: ...SiBE01 829 List of Function 1 Part 1 List of Function 1 Functions 2...
Страница 15: ...Functions SiBE01 829 4 List of Function...
Страница 16: ...SiBE01 829 Specifications 5 Part 2 Specifications 1 Specifications 6...
Страница 19: ...Specifications SiBE01 829 8 Specifications...
Страница 23: ...Printed Circuit Board Connector Wiring Diagram SiBE01 829 12 Printed Circuit Board Connector Wiring Diagram...
Страница 81: ...Check SiBE01 829 70 Service Diagnosis...
Страница 86: ...Others SiBE01 829 108 Others...
Страница 92: ...Wiring Diagrams SiBE01 829 114 Appendix...
Страница 96: ...SiBE01 829 iv Drawings Flow Charts...