
Indoor Unit
SiBE01-503
72
Removal Procedure
1. Indoor Unit
1.1
Removal of
Air Filter
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. External features
If ON/OFF button is kept
pushing for 5 seconds, a
forced cooling operation will
be carried out for approx. 15
minutes.
When the
signal receiver
catches a signal from the
remote controller, it
produces beep sound and
the operation lamp blinks.
2. Remove the air filters.
1
Pull protrusions on left
and right sides of panel
with fingers and open
front grille all the way.
2
Lift center section of air
filter and disengage
hooks.
Remove air filter by
pulling forward.
Left and right filters are
interchangeable.
To re-install, insert air filter
along the guide.
Содержание FTYN25DV3B ATY20DV2
Страница 1: ...SiBE01 503 SPLIT Pair D Series Applied Models zNon Inverter Pair Heat Pump...
Страница 5: ...SiBE01 503 iv Table of Contents Index i Drawings Flow Charts iii...
Страница 10: ...SiBE01 503 List of Function 1 Part 1 List of Function 1 Functions 2...
Страница 13: ...Functions SiBE01 503 4 List of Function...
Страница 14: ...SiBE01 503 Specifications 5 Part 2 Specifications 1 Specifications 6...
Страница 21: ...Printed Circuit Board Connector Wiring Diagram SiBE01 503 12 Printed Circuit Board Connector Wiring Diagram...
Страница 35: ...Control Specification SiBE01 503 26 Functions and Control...
Страница 59: ...Instructions SiBE01 503 50 System Configuration...
Страница 79: ...Check SiBE01 503 70 Service Diagnosis...
Страница 117: ...Others SiBE01 503 108 Others...