ESIE17-19C
|
Part 3. Repair
3.3. Unit specific repair procedures
19/08/19
|
Version 1.1
Page 87
Optimized Heating 4
3.3.2.6. Replacing DC fan motor assembly
PRELIMINARY ACTIONS
1. Switch off the Daikin unit via the user interface.
2. Switch off the Daikin unit with the field supplied circuit breaker.
3. Remove the propeller fan blade assembly, refer to
"Replacing propeller fan blade assembly single fan outdoor unit" on
PROCEDURE
Removal
1. Remove the insulation (
) from the switch box.
2. Unplug the fan motor connector (
) from the main PCB.
3. Release the fan motor assembly harness (
4. Slightly bend the harness retainers (
) to release the fan motor assembly harness (
).
5. Loosen and remove the screws (
) that fix the DC fan motor assembly (
6. Remove the DC fan motor assembly (
).
W
ARNING
: R
ISK
OF
F
IRE
When reconnecting a connector to the PCB, do not apply force, as this may damage the connector or connector pins of
the PCB.