Control Specification (15/18/24 Class)
SiUS04-904
60
Function and Control
4.13.3 Refrigerant Shortage Control
Outline
If a power consumption is below the specified value in which the frequency is higher than the
specified frequency, it must be regarded as refrigerant shortage.
In addition to such conventional function, if the discharge pipe temperature is higher than the target
discharge pipe temperature, and the electronic expansion valve is fully open (450 pulses) more
than the specified time, it is considered as refrigerant shortage.
With the conventional function, a power consumption is low comparing with that in the normal
operation when refrigerant is insufficient, and refrigerant shortage is detected by checking a power
consumption.
When operating with refrigerant shortage, although the rise of discharge pipe temperature is great
and the electronic expansion valve is open, it is presumed as refrigerant shortage if the discharge
pipe temperature is higher than the target discharge pipe temperature.
Refer to “Refrigerant Shortage” on page 138 for detail.
Detail
Judgment by Input Current
When an output frequency is exceeds 55 Hz and the input current is less than specified value, the
adjustment is made for refrigerant shortage.
Judgment by Discharge Pipe Temperature
When discharge pipe temperature is
36°F higher than target value and the electronic expansion
value opening is 450 plus (max.), the adjustment is made for refrigerant shortage.
Frequency
Power consumption
Refrigerant shortage zone
55 Hz
(R2834)
Refrigerant shortage
zone
(R1391)
Содержание FTXS09HVJU
Страница 1: ...SiUS04 904 Applied Models Inverter Pair Heat Pump Inverter Pair Wall Mounted Type H Series...
Страница 9: ...Safety Considerations SiUS04 904 viii Safety Considerations...
Страница 10: ...SiUS04 904 List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 13: ...SiUS04 904 4 Specifications Part 2 Specifications 1 Specifications 5 1 1 SEER 16 Models 5 1 2 SEER 13 Models 8...
Страница 30: ...Printed Circuit Board Connector Wiring Diagram SiUS04 904 Printed Circuit Board Connector Wiring Diagram 21...
Страница 72: ...Control Specification 15 18 24 Class SiUS04 904 62 Function and Control...
Страница 77: ...FTXS09 12HVJU SiUS04 904 66 Operation Manual...
Страница 78: ...SiUS04 904 FTXS09 12HVJU Operation Manual 67...
Страница 83: ...FTXS09 12HVJU SiUS04 904 72 Operation Manual is no longer displayed on the LCD...
Страница 84: ...SiUS04 904 FTXS09 12HVJU Operation Manual 73 is no longer displayed on the LCD...
Страница 85: ...FTXS09 12HVJU SiUS04 904 74 Operation Manual...
Страница 86: ...SiUS04 904 FTXS09 12HVJU Operation Manual 75...
Страница 87: ...FTXS09 12HVJU SiUS04 904 76 Operation Manual 3P232717 1C...
Страница 90: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 79 is no longer displayed on the LCD...
Страница 91: ...FTXS15 18 24HVJU SiUS04 904 80 Operation Manual...
Страница 94: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 83 is no longer displayed on the LCD...
Страница 95: ...FTXS15 18 24HVJU SiUS04 904 84 Operation Manual Do not hit or forcefully push the operation...
Страница 96: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 85 is no longer displayed on the LCD...
Страница 97: ...FTXS15 18 24HVJU SiUS04 904 86 Operation Manual is no longer displayed on the LCD...
Страница 98: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 87 is no longer displayed on the LCD...
Страница 99: ...FTXS15 18 24HVJU SiUS04 904 88 Operation Manual...
Страница 100: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 89...
Страница 101: ...FTXS15 18 24HVJU SiUS04 904 90 Operation Manual 3P232717 2C...