1-14

COOL/HEAT

(GREEN/RED)

Operation

GREEN

Cool mode

RED

Heat mode

RED

Auto mode in Heating operation

GREEN

Auto mode in Cooling operation

Timer on

Sleep mode on

GREEN

Fan mode on

GREEN

Dry mode on

RED

Defrost operation

GREEN

Unit error

 

ON

 

Blinking

IR Signal Receiver

When an infrared remote control operating signal has been 
transmitted, the signal receiver on the indoor unit will respond 
as below to con

fi

 rm acceptance of the signal transmission.

LED Indicator Lights for Cooling Unit/Heat Pump 
Unit

IR Receiver

Cooling Unit/Heat Pump Unit

The table shows the LED indicator lights for the air conditioner 
unit under normal operation and fault conditions. The LED 
indicator lights are located at the side of the air conditioner 
unit.
The heat pump units are equipped with an “auto” mode 
sensor whereby it will provide reasonable room temperature 
by switching automatically to either “cool” or “heat” mode 
according to the temperature set by the user.

ON/OFF

Cool/Heat
Timer
Sleep

ON/OFF switch

IR Receiver

INDICATOR LIGHTS

ON to OFF

1 Long Beep

OFF to ON
Pump down / Cool force on

2 Short Beep

Others

1 Short Beep

LED Indicator Lights: Normal Operation And Fault Conditions For Cooling/Heat Pump Unit

1 IM-5WMYJ-1113(2)DK_EN-39396B.i14   14

1 IM-5WMYJ-1113(2)DK_EN-39396B.i14   14

4/23/14   12:02:16 PM

4/23/14   12:02:16 PM

Содержание FTXN25MV1B

Страница 1: ...FTK35JXV1 RK35FXV1 FTK50JXV1 RK50CXV1 FTK60JXV1 RK60CXV1 Installation Manual R410A Split Series Manuale d installazione Serie Multiambienti R410A Installationsanleitung Split Baureihe R410A Manual de...

Страница 2: ...CVR IM 5WMYJ 1113 2 DK EN 39396B2 2 CVR IM 5WMYJ 1113 2 DK EN 39396B2 2 4 23 14 12 07 15 PM 4 23 14 12 07 15 PM...

Страница 3: ...R INSIDE NAME PLATE TERMINAL BLOCK WITH EARTH TERMINAL F E J G G L D B K M A Gas pipe end INSTALLATION PLATE 25 35 Liquid pipe end Through the wall hole 65mm All dimensions are in mm Drain hose positi...

Страница 4: ...mm Drain hose position Liquid pipe end Gas pipe end INSTALLATION PLATE 50 60 Recommended mounting plate retention spots 7 spots in all All dimensions are in mm Recommended mounting plate retention spo...

Страница 5: ...XN RK All dimensions are in mm Dimension Model A B C D E F G H I J K L M N 50 60 855 730 328 520 179 46 93 149 101 113 603 126 164 15 All dimensions are in mm Dimension Model O P Q R S T U V 50 60 34...

Страница 6: ...melt or deform as a result of excessive heat or chemical reaction When the unit is used in kitchen keep flouraway from going into suction of the unit This unit is not suitable for factory used where...

Страница 7: ...the inside of the service cover factory refrigerant charge of the product see unit name plate 2 additional refrigerant amount charged in the field total refrigerant charge contains fluorinated greenho...

Страница 8: ...ove the service lid screws 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down 500mm from wall Where a wall or other obstacle is in the path of outdoor unit s intake o...

Страница 9: ...the upper part of the unit please allow more space than the figure indicated in the above table Dimension A B C D Minimum Distance mm 300 1000 300 500 Condensed Water Disposal Of Outdoor Unit Heat Pum...

Страница 10: ...the side and bottom out hold the bottom of the piping and then position it to the required direction The condensation drain hose can be taped to the pipes Right side right back or right bottom piping...

Страница 11: ...25 35 FTK 25 35 When stripping the ends of interconnecting wires in advance bind right ends of wires with insulating tape Hand indoor unit s hook here Mounting plate Interconnecting wires Wire guide...

Страница 12: ...IGERANT PIPING Additional Charge The refrigerant is pre charged in the outdoor unit If the piping length is less than 7 5m then additional charge after vacuuming is not necessary If the piping length...

Страница 13: ...pes The exact length of pipe protruding from the top surface of the swaging block is determined by the flaring tool See Figure III Fix the pipe firmly on the swaging block Match the centers of both th...

Страница 14: ...terminal connectors and wires Make sure all the covers are properly fixed to avoid any gap Use round crimp style terminal for connecting wires to the power supply terminal block Connect the wires by...

Страница 15: ...from the valve and the service port Connect the center of the charging gauge to the vacuum pump Connect the charging gauge to the service port of the 3 way valve Start the vacuum pump Evacuate for app...

Страница 16: ...ows the LED indicator lights for the air conditioner unit under normal operation and fault conditions The LED indicator lights are located at the side of the air conditioner unit The heat pump units a...

Страница 17: ...EMP CWB Heat Pump Model INDOOR TEMP CDB OPERATING RANGE DB Dry bulb WB Wet bulb DB Dry bulb WB Wet bulb Model FTXN 25 35 RXN 25 35 20 15 0 3 7 2 5 2 0 1 20 18 10 0 10 15 20 50 46 43 40 30 20 10 10 14...

Страница 18: ...hildren If you keep this Bio Filter for a long time please keep it unopened and store in a cool place avoiding direct sunlight Please dispose the old Bio Filter as nonflammable garbage after use Opera...

Страница 19: ...Remove any dust adhering to the filter by using a vacuum cleaner or wash in lukewarm water below 40 C 104 F with a neutral cleaning detergent Rinse the filter well and dry before placing it back onto...

Страница 20: ...h might have adhered onto the coil Condensation on the front air grille of the indoor unit 5 This is caused by air humidity after an extended long period of operation The set temperature is too low in...

Страница 21: ...de este manual y en su traducci n a cualquier idioma prevalecer la versi n inglesa El fabricante se reserva el derecho a modificar cualquiera de las especificaciones y dise os contenidos en el present...

Отзывы: