Trial Operation
SiBE041434E
111
Trial Operation and Field Settings
3. Trial Operation
Outline
Carry out the trial operation in accordance with the operation manual to ensure that all functions
and parts, such as flap movement, are working properly.
Trial operation should be carried out in either cooling or heating operation.
Detail
1. Measure the power supply voltage and make sure that it falls within the specified range.
2. In cooling operation, select the lowest programmable temperature (18°C); in heating
operation, select the highest programmable temperature (30°C).
Trial operation may be disabled in either operation mode depending on the room
temperature.
After trial operation is complete, set the temperature to a normal level (26°C ~ 28°C in
cooling, 20°C ~ 24°C in heating operation).
For protection, the system does not start for 3 minutes after it is turned off.
ARC466 Series
(1) Press the
On/Off
button to turn on the system.
(2) Press the center of the
Temp
button and the
Mode
button at the same time.
(3) Select
T
(trial operation) with the
Temp
or
Temp
button.
(4) Press the
Mode
button to start the trial operation.
(5) Press the
Mode
button and select operation mode.
(6) Trial operation terminates in approximately 30 minutes and switches into normal mode. To
quit trial operation, press the
On/Off
button.
(R19935)
(2) (4) (5)
(1) (6)
(2) (3)
(3)
Содержание FTXM-K Series
Страница 16: ...SiBE041434E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Страница 18: ...SiBE041434E 3 Specifications Part 2 Specifications 1 Specifications 4...
Страница 66: ...SiBE041434E 51 Remote Controller Part 5 Remote Controller 1 20 25 Class 52 2 35 42 50 Class 54...
Страница 122: ...Check SiBE041434E 107 Service Diagnosis 42 50 class R21204 W V U DC_P1 Power module DC_N1 Power module...
Страница 137: ...Revision History Month Year Version Revised contents 02 2015 SiBE041434E First edition...