1-16
ADDITIONAL INFORMATION
ELECTRIC CHARACTERISTICS
Unit Combination
Power Supply
Compressor
OFM
IFM
Indoor Unit
Outdoor Unit
Hz - Volts
Voltage Range
MCA
MFA
RHz
RLA
W
FLA
W
FLA
FTKK09PXVJL
RKK09PXVJL
60 - 208
Min. 187 V
Max. 253 V
6.95
15
72
6.75
41
0.19
18
0.20
60 - 230
FTKK12PXVJL
RKK12PXVJL
60 - 208
Min. 187 V
Max. 253 V
7.70
15
80
7.50
41
0.19
18
0.20
60 - 230
FTKK18PXVJL
RKK18PXVJL
60 - 208
Min. 187 V
Max. 253 V
13.2
20
89
13
61
0.50
40
0.24
60 - 230
FTKK24PXVJL
RKK24PXVJL
60 - 208
Min. 187 V
Max. 253 V
13.2
20
85
13
61
0.50
40
0.24
60 - 230
FTXK09PXVJL
RXK09PXVJL
60 - 208
Min. 187 V
Max. 253 V
6.95
15
80
6.75
41
0.19
18
0.20
60 - 230
FTXK12PXVJL
RXK12PXVJL
60 - 208
Min. 187 V
Max. 253 V
7.95
15
90
7.75
41
0.19
18
0.20
60 - 230
FTXK18PXVJL
RXK18PXVJL
60 - 208
Min. 187 V
Max. 253 V
16.2
20
103
16
61
0.50
40
0.24
60 - 230
FTXK24PXVJL
RXK24PXVJL
60 - 208
Min. 187 V
Max. 253 V
16.2
20
103
16
61
0.50
40
0.24
60 - 230
FTKK09PXVJX
RKK09PXVJX
60 - 220
Min. 198 V
Max. 264 V
6.95
15
72
6.75
41
0.19
18
0.20
60 - 240
FTKK12PXVJX
RKK12PXVJX
60 - 220
Min. 198 V
Max. 264 V
7.70
15
80
7.50
41
0.19
18
0.20
60 - 240
FTKK18PXVJX
RKK18PXVJX
60 - 220
Min. 198 V
Max. 264 V
13.2
20
89
13
61
0.50
40
0.24
60 - 240
FTKK24PXVJX
RKK24PXVJX
60 - 220
Min. 198 V
Max. 264 V
13.2
20
85
13
61
0.50
40
0.24
60 - 240
FTXK09PXVJX
RXK09PXVJX
60 - 220
Min. 198 V
Max. 264 V
6.95
15
80
6.75
41
0.19
18
0.20
60 - 240
FTXK12PXVJX
RXK12PXVJX
60 - 220
Min. 198 V
Max. 264 V
7.95
15
90
7.75
41
0.19
18
0.20
60 - 240
FTXK18PXVJX
RXK18PXVJX
60 - 220
Min. 198 V
Max. 264 V
16.2
20
103
16
61
0.50
40
0.24
60 - 240
FTXK24PXVJX
RXK24PXVJX
60 - 220
Min. 198 V
Max. 264 V
16.2
20
103
16
61
0.50
40
0.24
60 - 240
Binding up pipes
Bind up the refrigerant pipe, electrical wire and drain hose with the band.
Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain
degree, separate the indoor power and then separate the drain hose.Bind them evenly.
The liquid pipe and gas pipe should be bound separately at the end.
Indoor unit
Gas
pipe
Band
Liquid
pipe
Refrigerant pipe
Drain hose
Band
Drain hose
Indoor and
outdoor electrical wire
electrical wire
Note:
1. The electrical wire and control wire cant be crossed or winding.
2. The drain hose should be bound at the bottom.