Si04-306
Indoor Unit
Removal Procedure
153
3. Remove the fan motor.
1
Remove the
fan motor
.
Reassembling the fan motor
(1) When reassembling the fan
rotor, provide as much as
5mm of play between the
side face of the rotor and the
bottom frame.
(2) When reassembling the fan
motor, align the end of the
connector with the height of
★
for play.
4. Remove the
bearing
.
1
Remove the
fan rotor
.
The bearing is on the
left side.
2
Loosen the two screws
and remove the
mounting plate for the
bearing
.
3
The bearing is made of
rubber. Push it inwards
firmly and remove it.
Step
Procedure
Points
5mm
Side face of
bottom frame
Side face of rotor
(R2808)