Indoor Unit
Si04-306
146
Removal Procedure
9
Press the
receiver units
down and release the
claws on the upper
side, and then undo the
claws on the lower side.
Release the claws on the
upper side.
10
Cut the clamp.
11
The receiver units
contain four PCBs.
Remove each PCB with
releasing claws.
Disconnect every
connector from each
PCB.
Remove the receiver units
while pushing the claws of
connectors.
12
Cut the clamp.
Clamps should be always
available.
Fix it as it was before.
Step
Procedure
Points
Содержание FTKD50BVM
Страница 17: ...List of Functions Si04 306 8 List of Functions ...
Страница 35: ...Specifications Si04 306 26 Specifications ...
Страница 143: ...Check Si04 306 134 Service Diagnosis ...
Страница 187: ...Outdoor Unit Si04 306 178 Removal Procedure ...
Страница 191: ...Others Si04 306 182 Others ...
Страница 201: ...Wiring Diagrams Si04 306 192 Appendix FTKD 18 24 28 BVMS ...
Страница 203: ...Wiring Diagrams Si04 306 194 Appendix RKD 18 24 28 BVMS ...