Si01-406
Specifications
Specifications
7
220-230-240V 50Hz
Notes:
MAX. interunit piping length: 30m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
The data on the conditions (AS/NZS3823.1):
(Conditions)
Models
Indoor Units
FT50CV1A
FT60CV1A
Outdoor Units
R50CV1A
R60CV1A
Capacity
kW
5.3
6.6
Btu/h
18,100
22,500
kcal/h
4,560
5,680
Moisture Removal
L/h
2.9
5.2
Running Current
A
7.4-7.3-7.2
11.0-10.9-10.8
Power Consumption
W
1,600
2,390
Power Factor
%
98.3-95.3-92.6
98.8-95.3-92.2
COP
W/W
3.31
2.76
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
15.9
φ
15.9
Drain
mm
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Units
FT50CV1A
FT60CV1A
Front Panel Color
White
White
Air Flow Rate m³/min (cfm)
H
16.2 (572)
17.5 (618)
M
14.0 (494)
15.0 (530)
L
11.9 (420)
12.5 (441)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
43
43
Speed
Steps
5 Steps and Auto
5 Steps and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable/Washable/Mildew Proof
Removable/Washable/Mildew Proof
Running Current
A
0.19-0.18-0.17
0.21-0.20-0.19
Power Consumption
W
40
45
Power Factor
%
95.7-96.6-98.0
97.4-97.8-98.7
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
290×1,050×238
290×1,050×238
Packaged Dimensions (H×W×D)
mm
337×1,147×366
337×1,147×366
Weight
kg
12
12
Gross Weight
kg
17
17
Operation
Sound
H/M/L
dBA
43/39/35
46/41/36
Outdoor Units
R50CV1A
R60CV1A
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Rotary Type
Hermetically Sealed Rotary Type
Model
RC60V1TNRT
NH41VMDT
Motor Output
W
1,500
2,200
Refrigerant
Oil
Type
SUNISO 4GSD. I.
MS-32
Charge
L
0.85
1.20
Refrigerant
Type
R22
R22
Charge
kg
1.35
1.70
Air Flow Rate m³/min (cfm)
H
29-29.5-30 (1,024-1,041-1,059)
40-40.5-41 (1,412-1,430-1,447)
L
— (—)
23-24-25 (812-847-883)
Fan
Type
Propeller
Propeller
Motor Output
W
53
53
Running Current
A
7.21-7.12-7.03
10.79-10.70-10.61
Power Consumption
W
1,560
2,345
Power Factor
%
98.3-95.3-92.5
98.8-95.3-92.1
Starting Current
A
32-33.5-35
55-58-60
Dimensions (H×W×D)
mm
685×800×300
685×800×300
Packaged Dimensions (H×W×D)
mm
732×955×390
732×955×390
Weight
kg
49
61
Gross Weight
kg
54
66
Operation Sound
dBA
54-54-55
54-54-55
Drawing No.
3D045882
3D045883A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Standard
Cooling
Piping Length
JIS C 9612
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
5m
(Rated)
FT50CV1A
FT60CV1A
Capacity
kW
5.3
6.6
Running Current
A
7.6
11.3
Power Consumption
W
1,650
2,460
COP
W/W
3.21
2.68
Standard
Cooling
Piping Length
Power Supply
AS/NZS3823.1
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
7.5m
50Hz 230V
Содержание FT25CV1A
Страница 7: ...Si01 406 vi Table of Contents...
Страница 15: ...Functions Si01 406 4 List of Function...
Страница 21: ...Specifications Si01 406 10 Specifications...
Страница 31: ...Printed Circuit Board Connector Wiring Diagram Si01 406 20 Printed Circuit Board Connector Wiring Diagram...
Страница 189: ...R50 60CV1A Si01 406 178 Removal Procedure 6 Remove the screw 7 Take off the electrical parts box Step Procedure Points...
Страница 205: ...Wiring Diagrams Si01 406 194 Appendix...
Страница 209: ...Si01 406 iv Index...