![Daikin FLXS-BAVMB Скачать руководство пользователя страница 185](http://html.mh-extra.com/html/daikin/flxs-bavmb/flxs-bavmb_service-manual_502275185.webp)
SiBE05-722_B
Outdoor Unit - RK(X)S25/35G2V1B
Removal Procedure
174
3.5
Removal of Reactor / Partition Plate
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the reactor.
Preparation
Remove the outer panels
according to the “Removal of
Outer Panels / Fan Motor”.
Remove the electrical box
according to the "Removal of
Electrical Box".
1
Remove the screw and
remove the reactor.
2. Remove the partition
plate.
1
Remove the 2 screws.
(R7224)
Reactor
(R7225)
(R7226)
Partition plate