![Daikin FLXS-BAVMB Скачать руководство пользователя страница 143](http://html.mh-extra.com/html/daikin/flxs-bavmb/flxs-bavmb_service-manual_502275143.webp)
SiBE05-722_B
Indoor Unit
Removal Procedure
132
4
Hook is located on the
right side behind the
indoor heat exchanger.
Warning
Do not contaminate any gas
(including air) other than the
specified refrigerant (R-410A)
into refrigerating cycle.
(Contaminating of air or other
gas causes abnormal
temperature rise in
refrigerating cycle, and this
results in pipe breakage or
personal injuries.)
Warning
If gas leaks, repair the spot of
leaking, then collect all
refrigerant from the unit.
After conducting vacuum
drying, charge proper amount
of refrigerant.
5
Slide the indoor heat
exchanger to the right
to release the hook.
6
Remove the indoor heat
exchanger.
Step
Procedure
Points
Move to right
Remove
(R14207)