![Daikin FLXS-BAVMB Скачать руководство пользователя страница 153](http://html.mh-extra.com/html/daikin/flxs-bavmb/flxs-bavmb_service-manual_502275153.webp)
SiBE05-722_B
Outdoor Unit - RK(X)S25/35E2V1B
Removal Procedure
142
4
Disconnect the
connector for the
overload protector
[S40].
5
Disconnect the
connector for the
electronic expansion
valve coil [S20].
6
Disconnect the
connector for the four
way valve coil [S80].
Step
Procedure
Points
(R7217)
[S40]
(R7218)
[S20]
(R7219)
[S80]