12
• The system does not start when the display shows
“
” (UNDER CENTRALIZED CONTROL) and
it flashes for a few seconds after pressing an opera-
tion button.
This is because the system is under centralized control.
Flashes on the display indicates that the system cannot be
controlled by the remote controller.
• The system does not start immediately after the power
supply is turned on.
Wait 6 hours until the micro computer is prepared for oper-
ation.
• The outdoor unit is stopped.
This is because the room temperature has reached the set
temperature. The indoor unit switches to fan operation.
Cooling operation (automatic cooling operation): Lower
the set temperature.
Heating operation (automatic heating operation): Raise
the set temperature.
The operation starts after a while when the system is in
normal condition.
• The remote controller displays “
”, and air dis-
charge stops.
This is because the system automatically switches to
DEFROST operation to prevent a decrease in heating
capacity when frost on the outdoor unit increases.
After 6 to 8 minutes (maximum 10 minutes), the system
returns to its original operation.
II. WHITE MIST COMES OUT OF A UNIT
• When humidity is high during cooling operation. (In
oily or dusty places)
If the inside of an indoor unit is extremely contaminated,
the temperature distribution inside a room becomes
uneven. It is necessary to clean the inside of the indoor
unit. Ask your dealer for details on cleaning the unit. This
operation requires a qualified service person.
• When the system is changed over to HEATING OPER-
ATION after DEFROST OPERATION.
Moisture generated by DEFROST becomes steam and
exists.
When the remote controller display shows “
”,
defrosting operation is being used.
III. NOISE OF AIR CONDITIONERS
• A ringing sound after the unit is started.
This sound is generated by the temperature regulator
working.
It will quiet down after about a minute.
• A continuous flow “Shuh” sound is heard when the
systems is in COOLING or DEFROST OPERATION.
This is the sound of refrigerant gas flowing through both
indoor and outdoor units.
• A “Shuh” sound which is heard at the start or immedi-
ately after the stop of operation or which is heard at
the start or immediately after the stop of DEFROST
OPERATION.
This is the noise of refrigerant caused by flow stop and
flow change.
During heating operation, the system switches to
DEFROST operation automatically. The remote controller
shows “
”.
After 6 to 8 minutes (maximum 10 minutes), the system
returns to its original operation.
• A continuous low “Shah” sound is heard when the
system is in COOLING OPERATION or at a stop.
The noise is heard when the drain pump is in operation.
• A “Pishi-pishi” squeaking sound is heard when the
system is in operation or after the stop of operation.
Expansion and contraction of plastic parts caused by tem-
perature change makes this noise.
IV. DUST FROM THE UNITS
• Dust may blow out from the unit after starting opera-
tion from long resting time.
Dust absorbed by the unit blows out.
V. THE UNITS GIVE OFF ODORS
The unit absorbs the smell of rooms, furniture, cigarettes,
etc., and then emits them.
If odor is a concern, set the airflow rate to gentle or no air-
flow when the indoor temperature reaches the set temper-
ature.
For details, contact your Daikin dealer.
VI.THE LIQUID CRYSTAL OF THE REMOTE CONTROL-
LER SHOW “
”
• It happens immediately after the main power supply
switch is turned on.
This shows that the remote controller is in normal condition.
This continues temporary.
VII.THE AIR FLOW DIRECTION IS DIFFERENT FROM THE
DISPLAY.
• The air direction blades do not swing when Automatic
swing setting.
<When heating operation>
When room temperature is higher than the set temperature,
air is blown horizontally to prevent the cool air from being
blown directly onto anyone in the room.
After a while, air direction blades swings. (Refer to page 8)
• The movement of air direction blades is different from
the display.
<When heating operation>
When room temperature is higher than the set temperature,
air is blown horizontally to prevent the cool air from being
blown directly onto anyone in the room.
After a while, air direction blades changes it according to
the setting. (Refer to page 8)
VIII.THE UNIT DOES NOT COOL EFFECTIVELY
• Program dry operation.
Program dry operation is designed to lower the room tem-
perature as little as possible.
Lower the room temperature using cooling operation, and
then use program dry operation.
TROUBLE SHOOTING
I. If one of the following malfunctions occurs, take the
measures shown below and contact your dealer.
The system must be repaired by a qualified service person.
WARNING
• When the air conditioner is in abnormal conditions
(smell of something burning, etc), unplug the power
cord from the outlet, and contact your dealer
Continued operation under such circumstances may result
in a failure, electric shock, and fire.
• If a safety device such as a fuse, a breaker or an earth
leakage breaker frequently actuates;
Measure:
Do not turn on the main power supply switch.
• If the ON/OFF button does not properly work;
Measure:
Turn off the main power supply switch.
• If water leaks from unit.
Measure:
Stop the operation.